Skip to content
aiqbench takeAI & Society

aiqbench analysis

This study demonstrates that interpretable AI models can effectively screen for glaucoma using low-cost, handheld retinal cameras in resource-limited settings like West Africa, achieving performance comparable to clinical tabletop systems. By integrating feature-weight analysis and class activation mapping, the framework provides decision confidence scores and visual rationales that support clinical interpretation without relying on expensive infrastructure. The results highlight a viable pathway for deploying accessible AI-driven diagnostics in community health programs where specialist access is scarce.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Interpretable AI plus Handheld, Portable Retinal Photographs: A Low-Cost Glaucoma Screening Solution for West Africa

arXiv3 min read

arXiv:2609.25697v1 Announce Type: cross Abstract: Purpose: To develop and evaluate an interpretable artificial intelligence (AI) framework for glaucoma screening from low-cost portable, handheld retinal fundus photographs in a West African population and to compare its performance with clinical tabletop fundus imaging. Methods: We used data from a community-based study of 681 participants (1,362 eyes) in Nigeria, comprising 414 glaucoma, 478 glaucoma suspect, and 470 non-glaucoma eyes. Fundus photographs were acquired using the low-cost handheld, portable Volk Viva retinal camera and the Canon CR-2-AF tabletop camera. We fine-tuned component models separately to each device to perform vessel segmentation, cup and disc boundary segmentation, and feature extraction to detect optic nerve head features. A final classification model combined these components to classify scans as glaucoma, glaucoma suspect or non-glaucoma. Feature-weight analysis and Gradient-weighted Class Activation Mapping were used for interpretation. Results: The models performed well on both Volk Viva and Canon CR-2-AF images: Vessel segmentation: 0.98 Dice Coefficient (DC) (Volk) and 0.94 DC (Canon); Cup and disc segmentation: 0.95 DC (Volk) and 0.96 DC (Canon); Optic nerve head feature detection: area under the receiver operating characteristic curve (AUCs) of 0.83$\pm$0.03 (Volk) and 0.87$\pm$0.04 (Canon); Classification model: AUCs of 0.85$\pm$0.01 (Volk) and 0.93$\pm$0.01 (Canon). Reports for each image, present model decision confidence scores and decision-rationale visualizations to support clinical interpretation. Conclusions: Volk Viva results were reasonably comparable to Canon CR-2-AF in the component models and not far behind in classification. This shows that interpretable AI combined with low-cost, portable imaging may enhance community-level glaucoma screening, especially in settings with limited specialist access and resources.

Abstract:Purpose: To develop and evaluate an interpretable artificial intelligence (AI) framework for glaucoma screening from low-cost portable, handheld retinal fundus photographs in a West African population and to compare its performance with clinical tabletop fundus imaging. Methods: We used data from a community-based study of 681 participants (1,362 eyes) in Nigeria, comprising 414 glaucoma, 478 glaucoma suspect, and 470 non-glaucoma eyes. Fundus photographs were acquired using the low-cost handheld, portable Volk Viva retinal camera and the Canon CR-2-AF tabletop camera. We fine-tuned component models separately to each device to perform vessel segmentation, cup and disc boundary segmentation, and feature extraction to detect optic nerve head features. A final classification model combined these components to classify scans as glaucoma, glaucoma suspect or non-glaucoma. Feature-weight analysis and Gradient-weighted Class Activation Mapping were used for interpretation. Results: The models performed well on both Volk Viva and Canon CR-2-AF images: Vessel segmentation: 0.98 Dice Coefficient (DC) (Volk) and 0.94 DC (Canon); Cup and disc segmentation: 0.95 DC (Volk) and 0.96 DC (Canon); Optic nerve head feature detection: area under the receiver operating characteristic curve (AUCs) of 0.83$\pm$0.03 (Volk) and 0.87$\pm$0.04 (Canon); Classification model: AUCs of 0.85$\pm$0.01 (Volk) and 0.93$\pm$0.01 (Canon). Reports for each image, present model decision confidence scores and decision-rationale visualizations to support clinical interpretation. Conclusions: Volk Viva results were reasonably comparable to Canon CR-2-AF in the component models and not far behind in classification. This shows that interpretable AI combined with low-cost, portable imaging may enhance community-level glaucoma screening, especially in settings with limited specialist access and resources.

Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)

arXiv:2609.25697 [cs.CV]

(or arXiv:2609.25697v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2609.25697 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 356 words

Related coverage