Skip to content
Off-topic for aiqbench

Off-topic for aiqbench

This story was gathered from a source we follow but falls outside AI and quantum coverage, so there is no aiqbench take for it.

International atomic clock comparison achieving $5\times 10^{-18}$ uncertainty

arXiv2 min read

arXiv:2610.29980v1 Announce Type: cross Abstract: Two single-ion optical clocks, located in the United Kingdom and in Germany, are compared remotely via a 2220\,km long optical fiber link. Both clocks are based on the ${}^2S_{1/2} (F=0)\leftrightarrow {}^2F_{7/2} (F=3)$ electric octupole (E3) transition in $^{171}\text{Yb}^+$. Using more than $10^6$ seconds of measurement data, we determine a fractional frequency difference of $1.0(4.8)\times 10^{-18}$, demonstrating agreement of the independently developed systems. To our knowledge, this constitutes the first international clock comparison reaching a fractional uncertainty below $5\times 10^{-18}$, an important milestone towards an anticipated optical redefinition of the SI second. The measurement uncertainty is dominated by that of the relativistic redshift correction between the two sites, which includes time-varying gravity potential differences. We exploit the large baseline between the two clocks to search for violations of Lorentz invariance. In the absence of statistically significant modulations, we improve constraints on the Robertson-Mansouri-Sexl parameter $\alpha$ by approximately a factor of five in the uncertainty, and provide limits on corresponding parameters within the Standard-Model Extension framework.

Authors:A. Tofful, M. Filzinger, T. Schmidt, A. Amy-Klein, E. Benkler, E. Cantin, C. Chardonnet, E. A. Curtis, H. Denker, B. Dutta, J.-O. Gaudron, W. Huang, J. Kronjäger, A. Kuhl, R. Le Targat, B. Lipphardt, O. Lopez, S. Mukherjee, A. L. Parke, B. Pointard, P.-E. Pottie, P. J. Regan, M. Risaro, M. Schioppo, M. Steinel, J. Tunesi, X. Zhang, R. M. Godun, N. Huntemann

Abstract:Two single-ion optical clocks, located in the United Kingdom and in Germany, are compared remotely via a 2220\,km long optical fiber link. Both clocks are based on the ${}^2S_{1/2} (F=0)\leftrightarrow {}^2F_{7/2} (F=3)$ electric octupole (E3) transition in $^{171}\text{Yb}^+$. Using more than $10^6$ seconds of measurement data, we determine a fractional frequency difference of $1.0(4.8)\times 10^{-18}$, demonstrating agreement of the independently developed systems. To our knowledge, this constitutes the first international clock comparison reaching a fractional uncertainty below $5\times 10^{-18}$, an important milestone towards an anticipated optical redefinition of the SI second. The measurement uncertainty is dominated by that of the relativistic redshift correction between the two sites, which includes time-varying gravity potential differences. We exploit the large baseline between the two clocks to search for violations of Lorentz invariance. In the absence of statistically significant modulations, we improve constraints on the Robertson-Mansouri-Sexl parameter $\alpha$ by approximately a factor of five in the uncertainty, and provide limits on corresponding parameters within the Standard-Model Extension framework.

Atomic Physics (physics.atom-ph); Quantum Physics (quant-ph)

arXiv:2610.29980 [physics.atom-ph]

(or arXiv:2610.29980v1 [physics.atom-ph] for this version)

https://doi.org/10.48550/arXiv.2610.29980 arXiv-issued DOI via DataCite (pending registration)

Full text under the publisher's open licence · 248 words

Related coverage