This research advances Model Predictive Control for soft exoskeletons by integrating disturbance estimation to significantly reduce steady-state tracking errors during knee rehabilitation. By treating involuntary spasms and actuator compliance as dynamic disturbances rather than rigid constraints, the framework achieves sub-2 mrad error rates at high frequencies without relying on higher impedance gains. While promising for robotic assistive devices, the study explicitly notes that hardware trials and clinical safety certifications remain outside its current scope.
Interaction Dynamics MPC for Knee Rehabilitation Exoskeletons: A Closed-Loop SEA Outer-Loop Study
arXiv:2606.13485v3 Announce Type: replace-cross Abstract: Safe rehabilitation is an interaction-dynamics problem: the controller must regulate a prescribed motion while absorbing involuntary spasm, voluntary effort, actuator compliance, and model mismatch as disturbances. This paper instantiates the predictive interaction-dynamics framework of the base pHRI formulation on a SEA knee joint. SEA feedforward reduces the gravity-compensated knee to the same scalar double integrator as the base framework, while a dynamic-residual measurement from spring deflection supplies an interaction-disturbance observation. A steady-state target converts the estimated disturbance into a cancelling input, and a finite-horizon quadratic program regulates deviations from that target under range-of-motion, torque, and velocity constraints. The evaluation matches stiffness and damping across controllers so gains cannot be attributed to higher impedance. Under a motion-opposing $15\unit{Nm}$ step, classical impedance and MPC without estimation produce about $500\unit{mrad}$ steady-state error, whereas Kalman-augmented interaction MPC reduces this to $1.17\unit{mrad}$ at 100~Hz and $0.70\unit{mrad}$ at 500~Hz; the 500~Hz peak is $7.27\unit{mrad}$. In 30 randomized trials, the 95th-percentile peak is $21.57\unit{mrad}$. Bounded Assist-as-Needed scheduling, a corrective-channel energy tank, constrained OSQP stress cases, direct MuJoCo execution, and a posture-clamped MyoSuite knee slice are implemented. The framework holds on a single-mass, closed-inner-loop SEA approximation; an explicit two-mass plant with a finite-bandwidth, pole-placed inner torque loop (Section~VIII) confirms this for nominal tracking but shows delivered torque can overshoot the commanded bound by 21.7\% near saturation. Scope excludes clinical intent recognition, full-system passivity, safety certification, hardware trials, and multi-joint validation.
Abstract:Safe rehabilitation is an interaction-dynamics problem: the controller must regulate a prescribed motion while absorbing involuntary spasm, voluntary effort, actuator compliance, and model mismatch as disturbances. This paper instantiates the predictive interaction-dynamics framework of the base pHRI formulation on a SEA knee joint. SEA feedforward reduces the gravity-compensated knee to the same scalar double integrator as the base framework, while a dynamic-residual measurement from spring deflection supplies an interaction-disturbance observation. A steady-state target converts the estimated disturbance into a cancelling input, and a finite-horizon quadratic program regulates deviations from that target under range-of-motion, torque, and velocity constraints. The evaluation matches stiffness and damping across controllers so gains cannot be attributed to higher impedance. Under a motion-opposing $15\unit{Nm}$ step, classical impedance and MPC without estimation produce about $500\unit{mrad}$ steady-state error, whereas Kalman-augmented interaction MPC reduces this to $1.17\unit{mrad}$ at 100~Hz and $0.70\unit{mrad}$ at 500~Hz; the 500~Hz peak is $7.27\unit{mrad}$. In 30 randomized trials, the 95th-percentile peak is $21.57\unit{mrad}$. Bounded Assist-as-Needed scheduling, a corrective-channel energy tank, constrained OSQP stress cases, direct MuJoCo execution, and a posture-clamped MyoSuite knee slice are implemented. The framework holds on a single-mass, closed-inner-loop SEA approximation; an explicit two-mass plant with a finite-bandwidth, pole-placed inner torque loop (Section~VIII) confirms this for nominal tracking but shows delivered torque can overshoot the commanded bound by 21.7\% near saturation. Scope excludes clinical intent recognition, full-system passivity, safety certification, hardware trials, and multi-joint validation.
Systems and Control (eess.SY); Human-Computer Interaction (cs.HC); Neural and Evolutionary Computing (cs.NE); Robotics (cs.RO); Medical Physics (physics.med-ph)
arXiv:2606.13485 [eess.SY]
(or arXiv:2606.13485v3 [eess.SY] for this version)
Full text under the publisher's open licence · 257 words