This study applies simulation-based inference and neural posterior estimation to demonstrate that integrating ballistocardiography (BCG) with standard PPG and APW signals significantly enhances the accuracy of cardiovascular biomarker estimation. By resolving ill-posed inverse problems where traditional signals yield multimodal distributions, the research highlights a critical advancement in using machine learning for non-invasive cardiac diagnostics.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Impact of Multiple Non-Invasive Biosignals on Cardiovascular Biomarker Estimation via Simulation-Based Inference

arXiv3 min read

arXiv:2609.11969v1 Announce Type: cross Abstract: As the population ages, the number of patients with cardiovascular diseases continues to increase, highlighting the need for early detection before progression to severe and irreversible functional decline. Consequently, estimating cardiovascular biomarkers from non-invasive biosignals, such as photoplethysmography (PPG) and arterial pressure wave (APW) signals, has attracted increasing attention. These signals can be measured using wearable and cuff-type devices. Previous studies have used PPG and APW signals to estimate cardiovascular biomarkers. However, these signals exhibit strong similarities in both the temporal and frequency domains and primarily reflect peripheral and arterial pulse waveforms. Therefore, they may provide limited information about cardiac mechanical function. In contrast, the quantitative impact of additional biosignals, such as ballistocardiography (BCG), which reflect the body's minute mechanical responses to cardiac ejection, remains unclear. In this study, we generated synthetic PPG, APW, and BCG signals from a unified whole-body cardiovascular circulation model and evaluated the complementary contribution of BCG to probabilistic cardiovascular biomarker estimation. We estimated posterior distributions of cardiovascular biomarkers using neural posterior estimation and simulation-based inference. The results showed that adding BCG signals significantly improved estimation performance. Furthermore, even in ill-posed cases where PPG and APW alone produced multimodal posterior distributions, adding BCG yielded unimodal posterior distributions. These findings provide fundamental insights into signal selection for estimating cardiovascular dynamics.

Abstract:As the population ages, the number of patients with cardiovascular diseases continues to increase, highlighting the need for early detection before progression to severe and irreversible functional decline. Consequently, estimating cardiovascular biomarkers from non-invasive biosignals, such as photoplethysmography (PPG) and arterial pressure wave (APW) signals, has attracted increasing attention. These signals can be measured using wearable and cuff-type devices. Previous studies have used PPG and APW signals to estimate cardiovascular biomarkers. However, these signals exhibit strong similarities in both the temporal and frequency domains and primarily reflect peripheral and arterial pulse waveforms. Therefore, they may provide limited information about cardiac mechanical function. In contrast, the quantitative impact of additional biosignals, such as ballistocardiography (BCG), which reflect the body's minute mechanical responses to cardiac ejection, remains unclear. In this study, we generated synthetic PPG, APW, and BCG signals from a unified whole-body cardiovascular circulation model and evaluated the complementary contribution of BCG to probabilistic cardiovascular biomarker estimation. We estimated posterior distributions of cardiovascular biomarkers using neural posterior estimation and simulation-based inference. The results showed that adding BCG signals significantly improved estimation performance. Furthermore, even in ill-posed cases where PPG and APW alone produced multimodal posterior distributions, adding BCG yielded unimodal posterior distributions. These findings provide fundamental insights into signal selection for estimating cardiovascular dynamics.

Medical Physics (physics.med-ph); Machine Learning (cs.LG); Applications (stat.AP)

arXiv:2609.11969 [physics.med-ph]

(or arXiv:2609.11969v1 [physics.med-ph] for this version)

https://doi.org/10.48550/arXiv.2609.11969 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 310 words

Related coverage