Skip to content
aiqbench takeAI + Quantum

aiqbench analysis

This research demonstrates a hybrid architecture where a supervised 3D $\beta$-VAE extracts disease-specific features from MRI data, which are then processed by quantum kernels to improve Alzheimer's classification accuracy. By integrating classical dimensionality reduction with quantum state encoding, the study achieves higher AUC scores and reduced variance compared to baseline models using pre-extracted inputs. The approach validates that end-to-end learning of domain-aware latent codes can effectively leverage quantum advantages in biomedical imaging tasks without relying on generic feature extraction pipelines.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Hybrid Classical-Quantum (HCQ) Alzheimer's Classification via Supervised $\beta$-VAE and Quantum Kernels

arXiv3 min read

arXiv:2606.14194v1 Announce Type: cross Abstract: This paper presents a two-stage Hybrid Classical-Quantum (HCQ) pipeline for binary Alzheimer's disease (AD) classification from 3D T1-weighted structural MRI volumes, where the classical and quantum components are designed to complement each other rather than operate independently. A supervised 3D $\beta$-variational autoencoder (VAE) is trained end-to-end under voxel-wise reconstruction, KL-divergence, and focal classification losses that compress each 3D MRI volume (resized from 152 x 184 x 152 to 96 x 96 x 96) into a 64-dimensional latent code. Partial Least Squares (PLS) regression selects the six components in the latent code that best separate Alzheimer's Disease (AD) from cognitively normal (CN) subjects and rescales them into rotation angles, which are encoded onto a six-qubit register using the ZZ quantum feature map to give us the respective quantum states. The input to a precomputed-kernel Support Vector Machine (SVM) is an N x N Gram matrix (N = 308), created by calculating the overlap between every pair of quantum states. The novelty of this work lies in the fact that the quantum kernel operates directly on disease-aware features that are learned end-to-end by a supervised autoencoder, rather than on pre-extracted inputs. On 308 ADNI-1 subjects, consisting of 137 AD and 171 CN subjects, the baseline achieved 67.2% accuracy and 0.759 AUC, while the stability-enhanced variant reached 72.1% accuracy and 0.799 AUC with cross-fold variance halved. 3D Grad-CAM further helped validate our model's focus on brain regions linked to Alzheimer's. The HCQ pipeline could serve as a general-purpose framework for diagnostic classification across biomedical imaging domains that present similar challenges for classical approaches.

Abstract: This paper presents a two-stage Hybrid Classical-Quantum (HCQ) pipeline for binary Alzheimer's disease (AD) classification from 3D T1-weighted structural MRI volumes, where the classical and quantum components are designed to complement each other rather than operate independently. A supervised 3D $\beta$-variational autoencoder (VAE) is trained end-to-end under voxel-wise reconstruction, KL-divergence, and focal classification losses that compress each 3D MRI volume (resized from 152 x 184 x 152 to 96 x 96 x 96) into a 64-dimensional latent code. Partial Least Squares (PLS) regression selects the six components in the latent code that best separate Alzheimer's Disease (AD) from cognitively normal (CN) subjects and rescales them into rotation angles, which are encoded onto a six-qubit register using the ZZ quantum feature map to give us the respective quantum states. The input to a precomputed-kernel Support Vector Machine (SVM) is an N x N Gram matrix (N = 308), created by calculating the overlap between every pair of quantum states. The novelty of this work lies in the fact that the quantum kernel operates directly on disease-aware features that are learned end-to-end by a supervised autoencoder, rather than on pre-extracted inputs. On 308 ADNI-1 subjects, consisting of 137 AD and 171 CN subjects, the baseline achieved 67.2% accuracy and 0.759 AUC, while the stability-enhanced variant reached 72.1% accuracy and 0.799 AUC with cross-fold variance halved. 3D Grad-CAM further helped validate our model's focus on brain regions linked to Alzheimer's. The HCQ pipeline could serve as a general-purpose framework for diagnostic classification across biomedical imaging domains that present similar challenges for classical approaches.

Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG)

arXiv:2606.14194 [cs.CV]

(or arXiv:2606.14194v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2606.14194 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 361 words

Related coverage