Skip to content
aiqbench takeAI Research

aiqbench analysis

Composing insight from the full article — this may take a moment.

Source coveringarXiv

Goal-Driven Autonomous Optical Experimentation via a Self-Recursive Hardware-Software Harness

arXiv2 min read

arXiv:2611.04481v1 Announce Type: new Abstract: We propose goal-driven self-recursive optical research in which agents use physical evidence to revise the hardware, software, models, and protocols used to pursue a scientific goal. The framework can be instantiated with different stimulus systems and measurement devices. We formalize its updates and derive a relation between physical attainability, command access, and model approximation error. We demonstrate the concept in an optical see-through color-matching case study using an iPad, RayNeo X3 glasses, and a TOP 300 probe coupled to a CAS140D spectroradiometer, both from Instrument Systems. A revised glasses application adds USB-controlled RGB holds and frame acknowledgements, keeping model-generated colors displayed during spectral acquisition. The interface passes 12 live control checks. Spectral feedback reduces one target color difference from 19.756 to 1.211 {\Delta}E_76^*; all five targets improve in a separate comparison. These measurements demonstrate the concept in one configuration. The resulting software and protocols remain available for subsequent investigations.

Abstract:We propose goal-driven self-recursive optical research in which agents use physical evidence to revise the hardware, software, models, and protocols used to pursue a scientific goal. The framework can be instantiated with different stimulus systems and measurement devices. We formalize its updates and derive a relation between physical attainability, command access, and model approximation error. We demonstrate the concept in an optical see-through color-matching case study using an iPad, RayNeo X3 glasses, and a TOP 300 probe coupled to a CAS140D spectroradiometer, both from Instrument Systems. A revised glasses application adds USB-controlled RGB holds and frame acknowledgements, keeping model-generated colors displayed during spectral acquisition. The interface passes 12 live control checks. Spectral feedback reduces one target color difference from 19.756 to 1.211 {\Delta}E_76^*; all five targets improve in a separate comparison. These measurements demonstrate the concept in one configuration. The resulting software and protocols remain available for subsequent investigations.

Artificial Intelligence (cs.AI); Multiagent Systems (cs.MA)

arXiv:2611.04481 [cs.AI]

(or arXiv:2611.04481v1 [cs.AI] for this version)

https://doi.org/10.48550/arXiv.2611.04481 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 246 words