aiqbench analysis

This research introduces GIFT, a novel framework for human-to-robot skill transfer that eliminates the need for shared tactile sensors by estimating robot-side forces through actuator current analysis. By decoupling the demonstration hardware from the deployment platform, the method enables any position-controlled robotic hand to replicate precise grip strategies learned via a standard wearable glove and vision inputs. The approach significantly improves grasp stability in force-critical tasks, advancing practical applications for collaborative robotics without requiring expensive sensor retrofitting on existing machines.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

GIFT: Glove-Inferred Force Transfer: Force-Aware Human-to-Robot Skill Transfer from a Wearable Sensing Glove to a Robot Hand Without Tactile Sensors

arXiv3 min read

arXiv:2609.14173v1 Announce Type: new Abstract: Human-to-robot skill transfer from sensing gloves has so far relied on shared hardware: the same tactile glove worn by the demonstrator and the robot, or a learned alignment between two tactile sensors. We present GIFT (Glove-Inferred Force Transfer), a pipeline in which the interface between human and robot is a physical unit rather than a shared sensor: fingertip force is measured in newtons on the human side and estimated in newtons on the robot side. A wearable glove records finger flexion, calibrated fingertip force, and wrist orientation, while a head-mounted camera records the demonstration; no robot is present. At deployment, the robot estimates force from actuator-current residuals relative to a free-space baseline, through a calibrated mapping to newtons, so any position-controlled hand that reports motor current can serve as the deployment platform. The policy uses a glove-space state and predicts finger-position targets; the robot enters only through two calibrated adapters, a retargeting decoder and a force estimator. We evaluate GIFT on a cup grasp-and-hold task with two action-chunking policies trained on the same demonstrations, with fingertip-force inputs retained in one and zeroed in the other. In a 50-rollout evaluation with sample size and metrics fixed before scoring, both policies succeeded in all 25 rollouts. The median of the per-rollout hold-phase grip-force estimates was 53% lower with force inputs: 1.20 N versus 2.55 N (one-sided Mann-Whitney U, p<0.0001). In an observation ablation, a vision-only policy achieved 0/15 grasps, policies given hand-command state acquired the grasp, and the force inputs determined how hard the policy held. A force channel measured on the human hand thus transfers to a robot hand with no tactile hardware, through a retargeting map from five glove channels to seven robot actuators, with no sensor shared between the two.

Abstract:Human-to-robot skill transfer from sensing gloves has so far relied on shared hardware: the same tactile glove worn by the demonstrator and the robot, or a learned alignment between two tactile sensors. We present GIFT (Glove-Inferred Force Transfer), a pipeline in which the interface between human and robot is a physical unit rather than a shared sensor: fingertip force is measured in newtons on the human side and estimated in newtons on the robot side. A wearable glove records finger flexion, calibrated fingertip force, and wrist orientation, while a head-mounted camera records the demonstration; no robot is present. At deployment, the robot estimates force from actuator-current residuals relative to a free-space baseline, through a calibrated mapping to newtons, so any position-controlled hand that reports motor current can serve as the deployment platform. The policy uses a glove-space state and predicts finger-position targets; the robot enters only through two calibrated adapters, a retargeting decoder and a force estimator. We evaluate GIFT on a cup grasp-and-hold task with two action-chunking policies trained on the same demonstrations, with fingertip-force inputs retained in one and zeroed in the other. In a 50-rollout evaluation with sample size and metrics fixed before scoring, both policies succeeded in all 25 rollouts. The median of the per-rollout hold-phase grip-force estimates was 53% lower with force inputs: 1.20 N versus 2.55 N (one-sided Mann-Whitney U, p<0.0001). In an observation ablation, a vision-only policy achieved 0/15 grasps, policies given hand-command state acquired the grasp, and the force inputs determined how hard the policy held. A force channel measured on the human hand thus transfers to a robot hand with no tactile hardware, through a retargeting map from five glove channels to seven robot actuators, with no sensor shared between the two.

7 pages, 5 figures, 1 table. Project page: this https URL

Robotics (cs.RO)

arXiv:2609.14173 [cs.RO]

(or arXiv:2609.14173v1 [cs.RO] for this version)

https://doi.org/10.48550/arXiv.2609.14173 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 395 words

Related coverage