aiqbench analysis
This study presents a GEGLU-Transformer architecture that effectively reconstructs muscle activation signals from inertial data, offering a robust alternative to traditional EMG sensors for wearable robotics. By leveraging few-shot adaptation techniques, the model achieves rapid personalization with minimal training data, addressing critical challenges in signal non-stationarity and subject variability. The findings validate attention-based mechanisms as a scalable solution for deploying neuromuscular control systems outside controlled laboratory environments.
GEGLU-Transformer for IMU-to-EMG Estimation with Few-Shot Adaptation
arXiv:2604.25670v2 Announce Type: replace Abstract: Reliable estimation of neuromuscular activation is a key enabler for adaptive and personalized control in wearable robotics. However, surface electromyography (EMG) remains difficult to deploy robustly outside laboratory settings due to electrode sensitivity, signal non-stationarity, and strong subject dependence. In this work, we propose an adaptive IMU-to-EMG learning framework that reconstructs continuous muscle activation envelopes from wearable inertial measurements across heterogeneous movement conditions. The approach combines a Transformer encoder with Gaussian Error Gated Linear Units (GEGLU-Transformer) to enhance cross-subject generalization and enable rapid subject-specific personalization. Under a strict leave-one-subject-out (LOSO) protocol on a multi-condition lower-limb biomechanics dataset, the proposed architecture achieves r = 0.706 +/- 0.139 and R^2 = 0.474 +/- 0.208 without subject-specific adaptation. With only 0.5% adaptation data, performance increases to r = 0.761 +/- 0.030 and R^2 = 0.559 +/- 0.047, demonstrating rapid adaptation and early performance saturation. These results support attention-based architectures combined with lightweight adaptation as a practical and scalable alternative to direct EMG sensing for real-world wearable robotic applications.
Abstract:Reliable estimation of neuromuscular activation is a key enabler for adaptive and personalized control in wearable robotics. However, surface electromyography (EMG) remains difficult to deploy robustly outside laboratory settings due to electrode sensitivity, signal non-stationarity, and strong subject dependence. In this work, we propose an adaptive IMU-to-EMG learning framework that reconstructs continuous muscle activation envelopes from wearable inertial measurements across heterogeneous movement conditions. The approach combines a Transformer encoder with Gaussian Error Gated Linear Units (GEGLU-Transformer) to enhance cross-subject generalization and enable rapid subject-specific personalization. Under a strict leave-one-subject-out (LOSO) protocol on a multi-condition lower-limb biomechanics dataset, the proposed architecture achieves r = 0.706 +/- 0.139 and R^2 = 0.474 +/- 0.208 without subject-specific adaptation. With only 0.5% adaptation data, performance increases to r = 0.761 +/- 0.030 and R^2 = 0.559 +/- 0.047, demonstrating rapid adaptation and early performance saturation. These results support attention-based architectures combined with lightweight adaptation as a practical and scalable alternative to direct EMG sensing for real-world wearable robotic applications.
Robotics (cs.RO)
arXiv:2604.25670 [cs.RO]
(or arXiv:2604.25670v2 [cs.RO] for this version)
https://doi.org/10.48550/arXiv.2604.25670 Focus to learn more arXiv-issued DOI via DataCite
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 256 words
Related coverage

Researchers Detect Relationships in Quantum Data with 15% Greater Accuracy
Quantum Zeitgeist · Sep 25, 2026

Enhanced measurements on quantum computers via the simultaneous probing of non-commuting Pauli operators
Quantum Journal · Oct 7, 2026

[AINews] Reality Checks on AI News (Yegge shuts down Gas Town, Databricks’ +60% Astra cost)
Latent Space · Sep 17, 2026
Adaptive Relational Learning on Multi-instance Quantum Data with Photonic Processors
arXiv · Sep 16, 2026