This research introduces FOCUS, a machine learning model that predicts continuous reliability weights for foot kinematics to reduce odometry drift in dynamic humanoid locomotion. By fusing these confidence scores with IMU data within an Extended Kalman Filter, the approach significantly lowers trajectory error without requiring manual annotations or reliable torque sensing. This advancement directly addresses critical proprioceptive challenges essential for robust autonomous robot navigation.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

FOCUS: Foot Observation Confidence for Robust Humanoid Proprioceptive Odometry

arXiv3 min read

arXiv:2609.02222v1 Announce Type: new Abstract: Foot forward kinematics (FK) is widely used to improve proprioceptive legged odometry by providing reliable velocity constraints during foot support. Existing contact-aided estimators generally rely on binary contact decisions to determine whether the FK measurements of an entire foot should be trusted. However, contact does not necessarily imply FK reliability. Dynamic locomotion often involves partial support, toe dragging, and foot slip, causing binary contact decisions to accumulate significant drift over long trajectories. To address this limitation, we propose FOCUS (Foot Observation Confidence from Unannotated Simulation), which predicts a continuous FK reliability weight for each foot instead of estimating binary foot contact. Rather than replacing the model-based estimator, the predicted reliability weights are used to blend FK velocity observations with IMU-propagated body velocity and to adapt the observation covariance of an extended Kalman filter (EKF), enabling smooth reliability-aware fusion without hard contact switching. The network is trained from automatically generated simulation signals using an FK-weighted velocity consistency loss with lightweight simulator-contact regularization, without manually annotated continuous FK-reliability labels. The deployed model relies only on IMU and joint kinematic measurements, making it suitable for hardware platforms with unreliable torque sensing. Experiments demonstrate that FOCUS reduces absolute trajectory error (ATE) by 83.7% on simulated walking episodes, preserves simulated dynamic-motion fidelity in motion scale and spectral energy, reduces ATE by 70.8% across 19 real walking segments, and reduces mean ATE by 42.7% across four real dynamic-motion routines.

Abstract:Foot forward kinematics (FK) is widely used to improve proprioceptive legged odometry by providing reliable velocity constraints during foot support. Existing contact-aided estimators generally rely on binary contact decisions to determine whether the FK measurements of an entire foot should be trusted. However, contact does not necessarily imply FK reliability. Dynamic locomotion often involves partial support, toe dragging, and foot slip, causing binary contact decisions to accumulate significant drift over long trajectories. To address this limitation, we propose FOCUS (Foot Observation Confidence from Unannotated Simulation), which predicts a continuous FK reliability weight for each foot instead of estimating binary foot contact. Rather than replacing the model-based estimator, the predicted reliability weights are used to blend FK velocity observations with IMU-propagated body velocity and to adapt the observation covariance of an extended Kalman filter (EKF), enabling smooth reliability-aware fusion without hard contact switching. The network is trained from automatically generated simulation signals using an FK-weighted velocity consistency loss with lightweight simulator-contact regularization, without manually annotated continuous FK-reliability labels. The deployed model relies only on IMU and joint kinematic measurements, making it suitable for hardware platforms with unreliable torque sensing. Experiments demonstrate that FOCUS reduces absolute trajectory error (ATE) by 83.7% on simulated walking episodes, preserves simulated dynamic-motion fidelity in motion scale and spectral energy, reduces ATE by 70.8% across 19 real walking segments, and reduces mean ATE by 42.7% across four real dynamic-motion routines.

Robotics (cs.RO)

arXiv:2609.02222 [cs.RO]

(or arXiv:2609.02222v1 [cs.RO] for this version)

https://doi.org/10.48550/arXiv.2609.02222 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 326 words

Related coverage