This research introduces Focal Calibration Loss (FCL) to address posterior distortion in deep classifiers by combining focal objectives with a squared probability-error anchor. The study rigorously quantifies how this anchor controls bias, offering theoretical guarantees on calibration error reduction across diverse datasets including medical and text tasks. While FCL improves specific metrics like NLL and Brier score, the analysis highlights that its advantages are regime-dependent and notably absent in transformer architectures.
Sources coveringarXiv, Latent Space
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Focal Calibration Loss: Controlling Posterior Distortion in Deep Neural Classifiers

arXiv3 min read

arXiv:2410.18321v3 Announce Type: replace Abstract: Confidence calibration matters wherever a classifier's probabilities, not just its labels, are consumed downstream. We study Focal Calibration Loss (FCL), which adds a squared probability-error (multiclass Brier) anchor to the focal objective, $\mathcal{L}{\mathrm{FCL}}^{\gamma,\lambda} = \mathcal{L}{\mathrm{focal}}^{\gamma} + \lambda |\hat{p}(x) - e_y|_2^2$. Our analysis separates two properties that are easily conflated: FCL is classification-calibrated for every $\gamma, \lambda \ge 0$, preserving the Bayes decision rule, yet for $\gamma > 0$ it is generally not proper, so its Bayes-optimal probability vector is displaced from the true posterior. The main result quantifies that displacement and shows the anchor controls it: bounded by $\sqrt{\log K / \lambda}$ for every posterior and minimizer without regularity assumptions, improving to $O(1/\lambda)$ for interior posteriors, with an exact first-order expansion identifying the bias and corresponding population $\ell_2$ calibration guarantees. We verify these population statements directly, minimizing the conditional risk on the simplex with no network involved: the posterior-distortion rate matches its prediction to a median fitted slope of $-0.994$, and exact population squared calibration error follows the predicted $\lambda^{-2}$ law (slopes $\approx -1.99$). Across CIFAR-10/100, Tiny-ImageNet, text and medical multi-label tasks, FCL is competitive rather than dominant, and the picture is regime- and metric-dependent: under a common validation-split protocol the validation-adaptive AdaFocal attains lower binned calibration error, while FCL attains lower NLL, Brier and error on two of three settings. On transformers its calibration advantage is absent, and a from-scratch experiment tested and did not support the conjecture that pretraining explains this. We report both the gains and the failure regimes.

Abstract:Confidence calibration matters wherever a classifier's probabilities, not just its labels, are consumed downstream. We study Focal Calibration Loss (FCL), which adds a squared probability-error (multiclass Brier) anchor to the focal objective, $\mathcal{L}{\mathrm{FCL}}^{\gamma,\lambda} = \mathcal{L}{\mathrm{focal}}^{\gamma} + \lambda |\hat{p}(x) - e_y|_2^2$. Our analysis separates two properties that are easily conflated: FCL is classification-calibrated for every $\gamma, \lambda \ge 0$, preserving the Bayes decision rule, yet for $\gamma > 0$ it is generally not proper, so its Bayes-optimal probability vector is displaced from the true posterior. The main result quantifies that displacement and shows the anchor controls it: bounded by $\sqrt{\log K / \lambda}$ for every posterior and minimizer without regularity assumptions, improving to $O(1/\lambda)$ for interior posteriors, with an exact first-order expansion identifying the bias and corresponding population $\ell_2$ calibration guarantees. We verify these population statements directly, minimizing the conditional risk on the simplex with no network involved: the posterior-distortion rate matches its prediction to a median fitted slope of $-0.994$, and exact population squared calibration error follows the predicted $\lambda^{-2}$ law (slopes $\approx -1.99$). Across CIFAR-10/100, Tiny-ImageNet, text and medical multi-label tasks, FCL is competitive rather than dominant, and the picture is regime- and metric-dependent: under a common validation-split protocol the validation-adaptive AdaFocal attains lower binned calibration error, while FCL attains lower NLL, Brier and error on two of three settings. On transformers its calibration advantage is absent, and a from-scratch experiment tested and did not support the conjecture that pretraining explains this. We report both the gains and the failure regimes.

Machine Learning (cs.LG); Computer Vision and Pattern Recognition (cs.CV); Machine Learning (stat.ML)

arXiv:2410.18321 [cs.LG]

(or arXiv:2410.18321v3 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2410.18321 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 353 words

Related coverage