Skip to content
Off-topic for aiqbench

Off-topic for aiqbench

This story was gathered from a source we follow but falls outside AI and quantum coverage, so there is no aiqbench take for it.

Feasibility of Embedded Photoplethysmography Sensing in Short-Duration Tactile Interactions With Pocket-Sized Robots Using IMU- and Confidence-Based Filtering

arXiv2 min read

arXiv:2608.04242v1 Announce Type: new Abstract: Ubiquitous companion robots offer a promising avenue for immediate anxiety relief in children, yet their effectiveness relies on the ability to monitor physiological states continuously and unobtrusively. Current solutions often depend on external wearables, which impose usability barriers and limit the robot's autonomy. This paper investigates the integration of an embedded photoplethysmography (PPG) sensor directly into a pocket-sized companion robot, AffectaPocket, to enable self-contained heart rate monitoring during tactile interaction. We address the significant challenge of motion artifacts inherent in handheld usage by implementing a two-stage filtering pipeline that utilizes an onboard Inertial Measurement Unit (IMU) to reject high-variance segments and a confidence-based smoothing algorithm for recovery periods. We evaluated the system against a commonly used wrist worn sensor in a Within-Subjects Study with 26 participants. Our results demonstrate that the filtering strategy significantly reduced the Mean Absolute Percentage Error and achieved statistical equivalence to the ground truth measurements (p<0.05). Analysis of short-duration interactions shows that the sensor requires stability over longer periods to converge.

Abstract:Ubiquitous companion robots offer a promising avenue for immediate anxiety relief in children, yet their effectiveness relies on the ability to monitor physiological states continuously and unobtrusively. Current solutions often depend on external wearables, which impose usability barriers and limit the robot's autonomy. This paper investigates the integration of an embedded photoplethysmography (PPG) sensor directly into a pocket-sized companion robot, AffectaPocket, to enable self-contained heart rate monitoring during tactile interaction. We address the significant challenge of motion artifacts inherent in handheld usage by implementing a two-stage filtering pipeline that utilizes an onboard Inertial Measurement Unit (IMU) to reject high-variance segments and a confidence-based smoothing algorithm for recovery periods. We evaluated the system against a commonly used wrist worn sensor in a Within-Subjects Study with 26 participants. Our results demonstrate that the filtering strategy significantly reduced the Mean Absolute Percentage Error and achieved statistical equivalence to the ground truth measurements (p<0.05). Analysis of short-duration interactions shows that the sensor requires stability over longer periods to converge.

Robotics (cs.RO)

arXiv:2608.04242 [cs.RO]

(or arXiv:2608.04242v1 [cs.RO] for this version)

https://doi.org/10.48550/arXiv.2608.04242 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 258 words

Related coverage