aiqbench analysis
This study reveals that benchmarking medical AI under information gaps yields inconsistent results depending on whether LLM judges or human clinicians evaluate model responses. The findings indicate a significant bias where models are rated more safely by their own developers' evaluators compared to independent clinical standards, suggesting current safety metrics may be inflated. Consequently, the reliability of open-ended conversational benchmarks is compromised unless standardized, blinded evaluation protocols replace provider-specific judging panels.
Evaluating medical AI under missing information: same-provider judges and human raters change apparent safety
arXiv:2607.18828v1 Announce Type: new Abstract: Readiness stress-testing of medical AI has focused on closed-ended and multimodal benchmarks. We extend it to open-ended clinical conversation under missing information, where safe behavior means recognizing absent information and qualifying, clarifying, or not over-committing - and where the evaluator becomes part of the measurement. We stress-test four models - three flagships (Claude Opus 4.8, GPT-5.5, Grok 4.3) and one mid-tier model (Gemini 3.5 Flash) - by deleting the latter half of the final user turn in HealthBench conversations, grading responses with a four-provider LLM-judge panel and a blinded clinician-anchored reference. Two evaluator-facing results are robust. First, judge choice materially changes apparent safety: inter-judge agreement is only moderate (Fleiss' kappa = 0.65), and after adjusting for each judge's general leniency (vote-level logistic regression), a positive same-provider association remains (exact permutation p = 0.04; GPT-5.5 ~ +0.10 on the probability scale) - large enough to change which model appears to over-commit least once its own-provider judge is excluded. Second, LLM judges are more permissive than clinicians on a blinded 50-item subsample: all four are significantly more lenient than the stricter independent clinician (crediting appropriate uncertainty on 66-84% of items vs 52%), and three of four than the author-influenced consensus (Grok directional only; judge-vs-consensus kappa = 0.20-0.43). On the author-audited clinical-underdetermined subset the permissiveness gap widened and the point-estimate model ordering held. A closed-ended MedQA anchor confirms accuracy is high and option-order effects are within a +/-5-point equivalence region for three of four models, so the safety gap is about calibration, not knowledge. We release the harness, prompts, per-item outputs, judge panel, perturbation audit, and human-annotation protocol.
Abstract:Readiness stress-testing of medical AI has focused on closed-ended and multimodal benchmarks. We extend it to open-ended clinical conversation under missing information, where safe behavior means recognizing absent information and qualifying, clarifying, or not over-committing - and where the evaluator becomes part of the measurement. We stress-test four models - three flagships (Claude Opus 4.8, GPT-5.5, Grok 4.3) and one mid-tier model (Gemini 3.5 Flash) - by deleting the latter half of the final user turn in HealthBench conversations, grading responses with a four-provider LLM-judge panel and a blinded clinician-anchored reference. Two evaluator-facing results are robust. First, judge choice materially changes apparent safety: inter-judge agreement is only moderate (Fleiss' kappa = 0.65), and after adjusting for each judge's general leniency (vote-level logistic regression), a positive same-provider association remains (exact permutation p = 0.04; GPT-5.5 ~ +0.10 on the probability scale) - large enough to change which model appears to over-commit least once its own-provider judge is excluded. Second, LLM judges are more permissive than clinicians on a blinded 50-item subsample: all four are significantly more lenient than the stricter independent clinician (crediting appropriate uncertainty on 66-84% of items vs 52%), and three of four than the author-influenced consensus (Grok directional only; judge-vs-consensus kappa = 0.20-0.43). On the author-audited clinical-underdetermined subset the permissiveness gap widened and the point-estimate model ordering held. A closed-ended MedQA anchor confirms accuracy is high and option-order effects are within a +/-5-point equivalence region for three of four models, so the safety gap is about calibration, not knowledge. We release the harness, prompts, per-item outputs, judge panel, perturbation audit, and human-annotation protocol.
Artificial Intelligence (cs.AI)
arXiv:2607.18828 [cs.AI]
(or arXiv:2607.18828v1 [cs.AI] for this version)
https://doi.org/10.48550/arXiv.2607.18828 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 359 words
Related coverage

Hint-based CoT faithfulness evals still mostly work on Claude
LessWrong · Jul 30, 2026

Underwriting Superintelligence: Backing Agents you can Sue — Rune Kvist, AIUC
Latent Space · Sep 16, 2026

How Flo Health built safer, more useful open models with Databricks AI Runtime
Databricks · Oct 12, 2026

Unlocking dependable responses with Gemini Enterprise Agent Platform’s Agentic RAG
Google Research · Jun 5, 2026