Skip to content
aiqbench takeQuantum Comms

aiqbench analysis

This research proposes a novel readout technique using Josephson Parametric Amplifiers to effectively halve the Standard Quantum Limit in high-Q haloscope experiments. By exploiting non-monochromatic axion signals, the method doubles measured signal power while maintaining constant vacuum noise, potentially enhancing sensitivity for dark matter detection.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Effective Sub-Quantum Readout for Non-Monochromatic Axion Signals in High-$Q$ Haloscopes

arXiv2 min read

arXiv:2609.02828v1 Announce Type: cross Abstract: The search for wave-like dark matter using microwave cavity haloscopes is constrained by the Standard Quantum Limit, which dictates that phase-preserving linear amplification results in a minimum of one quantum of total system noise for a narrow-band signal. We demonstrate that this limit is effectively halved for a non-monochromatic axion signal coupled to a high-$Q$ cavity. By operating a Josephson Parametric Amplifier such that the cavity resonance is centered exactly at the half-pump frequency, the axion signal symmetrically populates both the signal and idler bands. Through quadrature analysis of the homodyne readout, we show that the incoherent sum of these mirrored spectral components doubles the measured signal power while the vacuum noise remains constant. This operation yields an effective noise limit of 0.5 quanta per frequency bin, translating to an overall effective limit of $1/\sqrt{2}$ quanta after optimal matched filtering.

Abstract:The search for wave-like dark matter using microwave cavity haloscopes is constrained by the Standard Quantum Limit, which dictates that phase-preserving linear amplification results in a minimum of one quantum of total system noise for a narrow-band signal. We demonstrate that this limit is effectively halved for a non-monochromatic axion signal coupled to a high-$Q$ cavity. By operating a Josephson Parametric Amplifier such that the cavity resonance is centered exactly at the half-pump frequency, the axion signal symmetrically populates both the signal and idler bands. Through quadrature analysis of the homodyne readout, we show that the incoherent sum of these mirrored spectral components doubles the measured signal power while the vacuum noise remains constant. This operation yields an effective noise limit of 0.5 quanta per frequency bin, translating to an overall effective limit of $1/\sqrt{2}$ quanta after optimal matched filtering.

arXiv:2609.02828 [hep-ex]

(or arXiv:2609.02828v1 [hep-ex] for this version)

https://doi.org/10.48550/arXiv.2609.02828 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 231 words