Skip to content
aiqbench takeAI Products

aiqbench analysis

This paper introduces ECG-Scroll, a benchmark environment that challenges multimodal agents to interpret streaming ambulatory ECG data in real-time without access to future signals. By framing long-duration cardiac monitoring as a sequential decision process, it evaluates critical agent competencies like memory retention, tool use for signal measurement, and planning under causal constraints. This work addresses a fundamental gap where current models fail on paroxysmal events buried in hours of normal data, offering a rigorous testbed for next-generation diagnostic AI.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

ECG-Scroll: A Long-Horizon, Streaming Benchmark and Agent Environment for Interpretation of Ambulatory Electrocardiograms

arXiv3 min read

arXiv:2609.33117v1 Announce Type: new Abstract: Multimodal large language models (MLLMs) can now interpret a standard ten-second, twelve-lead electrocardiogram (ECG) with clinically grounded, reward-verified reasoning. Real cardiac monitoring is different. Ambulatory (Holter) and telemetry recordings span hours to days and are read as they stream in, and their clinically decisive findings are paroxysmal, brief episodes buried in an otherwise unremarkable trace. Such a recording cannot be held in one context at diagnostic resolution, and its future has not yet happened, so a reader must work online, deciding what to measure now, committing evidence to memory as it passes, and reporting events as they occur. We recast long-duration ECG interpretation as a long-horizon, online (streaming, causal) sequential decision process and introduce ECG-Scroll. As a benchmark, long ambulatory recordings are streamed to an agent chunk by chunk, and it must localize, quantify, and promptly flag paroxysmal events without access to future signal; because the underlying signal is retained, every answer is checkable against objective ground truth, giving rule-based rather than judge-based rewards, and the streaming formulation adds a metric batch evaluation cannot express, the detection latency between an event's onset and the moment the agent records it. As an agent environment, it is a fixed, gym-style interaction layer that exercises three competencies single-glance ECG models never touch: Memory, Tool use through signal-grounded measurement rather than reading pixels, and Planning of what to measure now and when to commit. We release 390 whole-recording instances spanning 2,536 hours of two-lead ambulatory ECG and evaluate a signal-threshold rule agent alongside off-the-shelf LLM agents online, characterizing how they use memory, tools, and planning and where the benchmark's head-room lies.

Abstract:Multimodal large language models (MLLMs) can now interpret a standard ten-second, twelve-lead electrocardiogram (ECG) with clinically grounded, reward-verified reasoning. Real cardiac monitoring is different. Ambulatory (Holter) and telemetry recordings span hours to days and are read as they stream in, and their clinically decisive findings are paroxysmal, brief episodes buried in an otherwise unremarkable trace. Such a recording cannot be held in one context at diagnostic resolution, and its future has not yet happened, so a reader must work online, deciding what to measure now, committing evidence to memory as it passes, and reporting events as they occur. We recast long-duration ECG interpretation as a long-horizon, online (streaming, causal) sequential decision process and introduce ECG-Scroll. As a benchmark, long ambulatory recordings are streamed to an agent chunk by chunk, and it must localize, quantify, and promptly flag paroxysmal events without access to future signal; because the underlying signal is retained, every answer is checkable against objective ground truth, giving rule-based rather than judge-based rewards, and the streaming formulation adds a metric batch evaluation cannot express, the detection latency between an event's onset and the moment the agent records it. As an agent environment, it is a fixed, gym-style interaction layer that exercises three competencies single-glance ECG models never touch: Memory, Tool use through signal-grounded measurement rather than reading pixels, and Planning of what to measure now and when to commit. We release 390 whole-recording instances spanning 2,536 hours of two-lead ambulatory ECG and evaluate a signal-threshold rule agent alongside off-the-shelf LLM agents online, characterizing how they use memory, tools, and planning and where the benchmark's head-room lies.

Machine Learning (cs.LG); Artificial Intelligence (cs.AI); Computation and Language (cs.CL); Signal Processing (eess.SP)

arXiv:2609.33117 [cs.LG]

(or arXiv:2609.33117v1 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2609.33117 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 371 words

Related coverage