This research presents a modular digital twin framework that integrates physical processes, 5G networks, and AI application logic to validate safety-critical industrial control loops before deployment. By experimentally comparing simulations with real-world data from an autonomous mobile robot, the study demonstrates how network modeling inaccuracies can compromise latency-sensitive operations when AI is executed at the edge or in the cloud. The work offers a practical methodology for engineers to assess the feasibility of deploying intelligent applications in complex industrial environments without risking operational safety.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Digital Twin for Pre-Deployment Validation of AI-Driven Safety-Critical Industrial Edge Control Loops

arXiv3 min read

arXiv:2610.11934v1 Announce Type: cross Abstract: Industrial environments are increasingly characterized by the tight interaction among physical processes, communication infrastructures, and intelligent applications. In this context, Digital Twins (DTs) have emerged as a key technology for system analysis and optimization. However, existing DT solutions typically focus either on industrial processes or communication networks, while lacking an integrated and application-aware perspective. To fill this gap, this paper proposes a modular DT framework for industrial environments that jointly models physical processes, wireless communications, and application logic within a unified architecture. The feasibility of the proposed framework is experimentally validated through a real-world Proof-of-Concept (PoC) implemented in the BI-REX pilot line, involving a 5G-connected Autonomous Mobile Robot (AMR) transporting hazardous liquids and remotely controlled by an AI-driven application. The proposed DT is used to reproduce the behaviour of the real deployment and to investigate the impact of different placements of the AI application, including on-premise, edge, and remote cloud execution scenarios. Experimental results demonstrate a close agreement between DT predictions and PoC measurements in terms of both network-level metrics, such as Reference Signal Received Power (RSRP) and latency, and end- to-end application metrics, including application-level Round- Trip-Time (RTT). Moreover, the analysis shows how inaccuracies of network modeling can critically affect the feasibility of latency-sensitive industrial control loops, highlighting the potential of integrated DTs as tools for the pre-deployment design and validation of next-generation industrial systems.

Abstract:Industrial environments are increasingly characterized by the tight interaction among physical processes, communication infrastructures, and intelligent applications. In this context, Digital Twins (DTs) have emerged as a key technology for system analysis and optimization. However, existing DT solutions typically focus either on industrial processes or communication networks, while lacking an integrated and application-aware perspective. To fill this gap, this paper proposes a modular DT framework for industrial environments that jointly models physical processes, wireless communications, and application logic within a unified architecture. The feasibility of the proposed framework is experimentally validated through a real-world Proof-of-Concept (PoC) implemented in the BI-REX pilot line, involving a 5G-connected Autonomous Mobile Robot (AMR) transporting hazardous liquids and remotely controlled by an AI-driven application. The proposed DT is used to reproduce the behaviour of the real deployment and to investigate the impact of different placements of the AI application, including on-premise, edge, and remote cloud execution scenarios. Experimental results demonstrate a close agreement between DT predictions and PoC measurements in terms of both network-level metrics, such as Reference Signal Received Power (RSRP) and latency, and end- to-end application metrics, including application-level Round- Trip-Time (RTT). Moreover, the analysis shows how inaccuracies of network modeling can critically affect the feasibility of latency-sensitive industrial control loops, highlighting the potential of integrated DTs as tools for the pre-deployment design and validation of next-generation industrial systems.

Networking and Internet Architecture (cs.NI); Robotics (cs.RO)

arXiv:2610.11934 [cs.NI]

(or arXiv:2610.11934v1 [cs.NI] for this version)

https://doi.org/10.48550/arXiv.2610.11934 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 324 words

Related coverage