aiqbench analysis
This study pioneers a deep learning framework using hybrid CNN-BiLSTM models to estimate ground reaction forces in Parkinson's disease patients via wearable IMUs, achieving high accuracy with optimized sensor configurations. The research demonstrates that while four sensors yield optimal results for pathological gait, a minimal two-sensor setup remains robust enough for scalable clinical monitoring and remote rehabilitation applications.
Deep Learning-Based Estimation of Ground Reaction Forces in Parkinsonian Gait Using an Optimized Set of IMU Data
arXiv:2608.02408v1 Announce Type: new Abstract: Accurate gait analysis in Parkinson's disease (PD) typically relies on laboratory-based systems to capture biomechanical data, such as ground reaction forces (GRFs). Estimating GRFs using inertial measurement units (IMUs) provides a feasible alternative. However, this approach remains challenging in pathological gait like PD due to its high variability and complexity. Moreover, existing monitoring approaches often require multiple body-mounted sensors, which limit practicality and reduce patient compliance. To date, no study has investigated the application of deep learning approaches to address this challenge. This study proposes, for the first time, a deep learning framework to estimate bilateral vertical GRFs (vGRFs) in PD using an optimized set of wearable IMUs. A hybrid CNN-BiLSTM model was trained separately on data from 61 PD patients and 65 healthy controls (HC) using 13 IMUs. The model achieved high intra-subject accuracy ($R^2$ = 0.98) and strong inter-subject generalization ($R^2$ = 0.93 for HC, $R^2$ = 0.91 for PD). Sensor configuration was found to significantly influence estimation accuracy, with optimal sensor placement varying between PD patients and HC. For PD patients, estimation accuracy dropped markedly when reducing to a single IMU. The optimal configuration for PD used four IMUs. We identified a minimal setup with only two IMUs still enabled robust estimation. This compact setup offers a practical and scalable solution. Overall, the proposed approach supports the development of wearable vGRF-based gait analysis systems for Parkinsonian gait and potentially other pathological conditions, enabling accessible clinical assessments, remote monitoring, and personalized rehabilitation.
Abstract:Accurate gait analysis in Parkinson's disease (PD) typically relies on laboratory-based systems to capture biomechanical data, such as ground reaction forces (GRFs). Estimating GRFs using inertial measurement units (IMUs) provides a feasible alternative. However, this approach remains challenging in pathological gait like PD due to its high variability and complexity. Moreover, existing monitoring approaches often require multiple body-mounted sensors, which limit practicality and reduce patient compliance. To date, no study has investigated the application of deep learning approaches to address this challenge. This study proposes, for the first time, a deep learning framework to estimate bilateral vertical GRFs (vGRFs) in PD using an optimized set of wearable IMUs. A hybrid CNN-BiLSTM model was trained separately on data from 61 PD patients and 65 healthy controls (HC) using 13 IMUs. The model achieved high intra-subject accuracy ($R^2$ = 0.98) and strong inter-subject generalization ($R^2$ = 0.93 for HC, $R^2$ = 0.91 for PD). Sensor configuration was found to significantly influence estimation accuracy, with optimal sensor placement varying between PD patients and HC. For PD patients, estimation accuracy dropped markedly when reducing to a single IMU. The optimal configuration for PD used four IMUs. We identified a minimal setup with only two IMUs still enabled robust estimation. This compact setup offers a practical and scalable solution. Overall, the proposed approach supports the development of wearable vGRF-based gait analysis systems for Parkinsonian gait and potentially other pathological conditions, enabling accessible clinical assessments, remote monitoring, and personalized rehabilitation.
13 pages, 5 figures, 6 tables. Published in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Machine Learning (cs.LG); Signal Processing (eess.SP)
arXiv:2608.02408 [cs.LG]
(or arXiv:2608.02408v1 [cs.LG] for this version)
https://doi.org/10.48550/arXiv.2608.02408 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
IEEE Transactions on Neural Systems and Rehabilitation Engineering, vol. 34, pp. 2729-2740, 2026
https://doi.org/10.1109/TNSRE.2026.3697513 Focus to learn more DOI(s) linking to related resources
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 380 words
Related coverage
Synthesis Superintelligence: from Semiconductors to Superconductors — Periodic Labs’ Liam Fedus and Ekin Dogus Cubuk
Latent Space · Oct 8, 2026

[AINews] not much happened today
Latent Space · Sep 10, 2026

[AINews] Reality Checks on AI News (Yegge shuts down Gas Town, Databricks’ +60% Astra cost)
Latent Space · Sep 17, 2026

It’s about ethics in journalism, with Ben Smith
The Verge · Aug 17, 2026