aiqbench analysis
This research introduces CVAF-Net, a dual-view deep learning architecture that effectively fuses raw temporal PPG signals with structured feature priors to estimate cardiac output from short sensor segments. By leveraging cross-view attention mechanisms, the model achieves state-of-the-art accuracy while reducing computational complexity by twelvefold compared to leading Transformer-based baselines. The approach demonstrates strong generalizability across simulated and real-world physiological conditions, offering a viable path for efficient, unobtrusive wearable hemodynamic monitoring.
Cross-View Attention Fusion Net: A Prior-Guided Dual-View Representation Learning for Cardiac Output Estimation from Short-Term PPG Signals
arXiv:2605.19666v2 Announce Type: replace-cross Abstract: Accurate cardiac output (CO) estimation from photoplethysmography (PPG) is promising for unobtrusive hemodynamic monitoring, but remains difficult since CO is jointly determined by cardiac function and vascular tone. Conventional feature-based models use physiologically meaningful PPG descriptors, yet depend on accurate pulse detection and may miss latent temporal relationships. In contrast, fully end-to-end deep learning models learn directly from raw PPG but often underuse established PPG-derived prior information. Here, we introduce the Cross-View Attention Fusion Network (CVAF-Net), a prior-guided dual-view deep learning model for CO estimation from short, fixed-length PPG segments. CVAF-Net processes raw PPG as a temporal view and a feature sequence map (FSM) as a structured prior-guided view, and fuses the two representations through cross-view attention. The model was independently evaluated using 5-, 15-, and 30-s segments from three datasets: simulated pulse waves (3323 subjects), vasoconstriction provocation (79 subjects), and resting/cycling activities (10 subjects), and was compared with multiple machine learning and deep learning benchmarks. CVAF-Net outperformed most benchmark methods and achieved performance comparable to a state-of-the-art Transformer-based model, with a mean absolute error (MAE) of 0.19 L/min (MAPE: 3.95%) on simulated data and high accuracy in real-world settings (minimum MAE: 1.20 L/min). Importantly, CVAF-Net reduced FLOPs by twelvefold compared with the leading Transformer-based model. Plausibility analysis showed physiologically consistent CO estimates, with expected correlations with age ($\rho = -0.274$), heart rate ($\rho = 0.894$), and systemic vascular resistance ($\rho = -0.740$). These findings indicate that CVAF-Net provides an accurate, computationally efficient, and generalizable approach for continuous wearable-based CO monitoring.
Abstract:Accurate cardiac output (CO) estimation from photoplethysmography (PPG) is promising for unobtrusive hemodynamic monitoring, but remains difficult since CO is jointly determined by cardiac function and vascular tone. Conventional feature-based models use physiologically meaningful PPG descriptors, yet depend on accurate pulse detection and may miss latent temporal relationships. In contrast, fully end-to-end deep learning models learn directly from raw PPG but often underuse established PPG-derived prior information. Here, we introduce the Cross-View Attention Fusion Network (CVAF-Net), a prior-guided dual-view deep learning model for CO estimation from short, fixed-length PPG segments. CVAF-Net processes raw PPG as a temporal view and a feature sequence map (FSM) as a structured prior-guided view, and fuses the two representations through cross-view attention. The model was independently evaluated using 5-, 15-, and 30-s segments from three datasets: simulated pulse waves (3323 subjects), vasoconstriction provocation (79 subjects), and resting/cycling activities (10 subjects), and was compared with multiple machine learning and deep learning benchmarks. CVAF-Net outperformed most benchmark methods and achieved performance comparable to a state-of-the-art Transformer-based model, with a mean absolute error (MAE) of 0.19 L/min (MAPE: 3.95%) on simulated data and high accuracy in real-world settings (minimum MAE: 1.20 L/min). Importantly, CVAF-Net reduced FLOPs by twelvefold compared with the leading Transformer-based model. Plausibility analysis showed physiologically consistent CO estimates, with expected correlations with age ($\rho = -0.274$), heart rate ($\rho = 0.894$), and systemic vascular resistance ($\rho = -0.740$). These findings indicate that CVAF-Net provides an accurate, computationally efficient, and generalizable approach for continuous wearable-based CO monitoring.
Medical Physics (physics.med-ph); Machine Learning (cs.LG)
arXiv:2605.19666 [physics.med-ph]
(or arXiv:2605.19666v2 [physics.med-ph] for this version)
https://doi.org/10.48550/arXiv.2605.19666 Focus to learn more arXiv-issued DOI via DataCite
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 346 words
Related coverage

Digital States 2026: AI Moves From Experiment to Infrastructure
govtech.com · Sep 24, 2026

[AINews] Reality Checks on AI News (Yegge shuts down Gas Town, Databricks’ +60% Astra cost)
Latent Space · Sep 17, 2026
DPSF-Net: A Dual-Prior Spatial-Frequency Network for Real-World Remote Sensing Image Dehazing
arXiv · Sep 9, 2026
AT-ViT: Area-Targeted Multi-View Vision Transformer with Cross-Attention and Multi-Scale Patching for Plant Trait Recognition in Herbarium Images
arXiv · Aug 24, 2026