Skip to content
aiqbench takeMachine Learning

aiqbench analysis

This research addresses the critical challenge of domain shift in medical imaging by demonstrating how class-wise dataset mixing can significantly improve cross-institution generalization for breast MRI tumor classification. By mitigating label-origin bias, the study provides actionable insights into making deep learning models more robust and reliable across diverse healthcare settings without relying on costly new data collection.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Cross-Dataset Generalization in Breast MRI Tumor Classification via Class-Wise Dataset Mixing

arXiv2 min read

arXiv:2607.18678v1 Announce Type: cross Abstract: Breast MRI is highly sensitive for detecting breast tumors, but exams contain many slices and require substantial reading time. Deep learning models often perform well on internal splits but can fail across institutions because of domain shift and dataset-origin bias. We study this failure mode for binary breast MRI tumor classification. EfficientNet-B3 and WaveViT-Small are trained using Duke Breast Cancer MRI and fastMRI, and evaluated only on the independent multi-center MAMA-MIA cohort. In a deliberately confounded setup, where label is perfectly correlated with dataset origin, external accuracy is near chance (0.5048--0.5265), despite very high recall. We then construct a mixed training set in which each class contains samples from both Duke and fastMRI, while preserving patient-level splitting, augmentation, and leakage controls. On MAMA-MIA, dataset mixing improves accuracy/F1 to 0.8463/0.8625 for WaveViT-Small and 0.8884/0.8994 for EfficientNet-B3. These results show that controlling dataset-origin bias is important for reliable breast MRI classification.

Abstract:Breast MRI is highly sensitive for detecting breast tumors, but exams contain many slices and require substantial reading time. Deep learning models often perform well on internal splits but can fail across institutions because of domain shift and dataset-origin bias. We study this failure mode for binary breast MRI tumor classification. EfficientNet-B3 and WaveViT-Small are trained using Duke Breast Cancer MRI and fastMRI, and evaluated only on the independent multi-center MAMA-MIA cohort. In a deliberately confounded setup, where label is perfectly correlated with dataset origin, external accuracy is near chance (0.5048--0.5265), despite very high recall. We then construct a mixed training set in which each class contains samples from both Duke and fastMRI, while preserving patient-level splitting, augmentation, and leakage controls. On MAMA-MIA, dataset mixing improves accuracy/F1 to 0.8463/0.8625 for WaveViT-Small and 0.8884/0.8994 for EfficientNet-B3. These results show that controlling dataset-origin bias is important for reliable breast MRI classification.

Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG)

arXiv:2607.18678 [cs.CV]

(or arXiv:2607.18678v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2607.18678 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 249 words

Related coverage