Skip to content
aiqbench takeQuantum Computing

aiqbench analysis

This study eliminates parasitic interfaces by replacing bandages with all-airbridge interconnects for Josephson junctions, significantly simplifying fabrication of superconducting qubits. The approach maintains high mechanical stability across a wide range of dimensions while preserving low loss and achieving relaxation times exceeding 250 µs in transmon geometries. This process optimization directly addresses manufacturing complexity and yield constraints critical for scaling superconducting quantum circuits.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Contacting Josephson Junctions via Airbridges in Superconducting Circuits

arXiv2 min read

arXiv:2606.06951v1 Announce Type: new Abstract: Superconducting circuit devices require electrical interconnects between different circuit elements on the chip, for which conventional device architectures use a combination of two structural elements: \textit{airbridges} to connect non-adjacent elements in the base layer, and \textit{bandages} to connect the electrodes forming the Josephson junctions to the base layer. Bandages introduce unwanted parasitic material interfaces and increase the manufacturing complexity. Here, we overcome the limitations imposed by \emph{bandages} by establishing \textit{all} electrical interconnects with airbridges of varying size fabricated in a single step. The airbridges show a high yield and mechanical stability over a wide range of sizes from $0.5\,\mu\mathrm{m}$ to $4\,\mu\mathrm{m}$ in width and from $5\,\mu\mathrm{m}$ to $40\,\mu\mathrm{m}$ in length, and show low loss when integrated in coplanar waveguide resonators and transmon qubits. Measured relaxation times up to more than $250\,\mu\mathrm{s}$ in standard transmon geometries show that the process achieves high coherence while substantially easing and accelerating device fabrication.

Abstract:Superconducting circuit devices require electrical interconnects between different circuit elements on the chip, for which conventional device architectures use a combination of two structural elements: \textit{airbridges} to connect non-adjacent elements in the base layer, and \textit{bandages} to connect the electrodes forming the Josephson junctions to the base layer. Bandages introduce unwanted parasitic material interfaces and increase the manufacturing complexity. Here, we overcome the limitations imposed by \emph{bandages} by establishing \textit{all} electrical interconnects with airbridges of varying size fabricated in a single step. The airbridges show a high yield and mechanical stability over a wide range of sizes from $0.5\,\mu\mathrm{m}$ to $4\,\mu\mathrm{m}$ in width and from $5\,\mu\mathrm{m}$ to $40\,\mu\mathrm{m}$ in length, and show low loss when integrated in coplanar waveguide resonators and transmon qubits. Measured relaxation times up to more than $250\,\mu\mathrm{s}$ in standard transmon geometries show that the process achieves high coherence while substantially easing and accelerating device fabrication.

arXiv:2606.06951 [quant-ph]

(or arXiv:2606.06951v1 [quant-ph] for this version)

https://doi.org/10.48550/arXiv.2606.06951 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 240 words

Related coverage