aiqbench analysis
This research addresses a critical challenge in non-destructive testing by using machine learning to infer subsurface defect depths from 2D thermal video, effectively preventing models from memorizing spatial grid patterns. By decoupling spatial localization from temporal heat-diffusion analysis and applying mathematical regularization, the approach achieves high-precision depth estimation that remains robust across different specimen geometries. The work demonstrates how advanced regression techniques can extract physical relationships from indirect sensor data without relying on volumetric measurements.
Computational Depth Measurement in Thermographic Video: Overcoming Spatial Overfitting via Spatio-Temporal Decoupling
arXiv:2608.29223v1 Announce Type: new Abstract: Accurate through-thickness measurement of subsurface delamination depth in Carbon Fiber Reinforced Polymer (CFRP) is important for structural assessment because defect location determines affected load-bearing layers. Optical pulsed thermography (OPT) provides a two-dimensional thermal video rather than volumetric measurements, so depth must be inferred from temporal heat-diffusion responses. A challenge is spatial dataset bias: when calibration defects follow regular grids, regression models may memorize their geometry instead of learning physical relationship between thermal decay and depth. This work introduces a spatio-temporal decoupling architecture that separates spatial defect localization from temporal depth measurement. Defect regions are first localized using segmentation methods, after which thermal responses are spatially averaged and converted into sixteen physics-informed temporal, energy, statistical, and geometric features. These features expose the one-dimensional heat-conduction relationship while withholding pixel coordinates from the depth model. Four regression models are evaluated using specimen-level cross-validation: Random Forest (RF), Gradient Boosting Machine (GBM), Advanced Multi-Layer Perceptron (Adv-MLP), and XGBoost. Unregularized trees and over-parameterized Adv-MLP exhibit calibration collapse under geometric shifts, with errors exceeding 0.5 mm. In contrast, regularized XGBoost with L1/L2 penalties and column sampling maintains cross-specimen calibration, achieving a mean absolute error (MAE) of 0.056 mm and root mean square error (RMSE) of 0.085 mm. Predicted depths are merged with masks to generate Delaunay-triangulated three-dimensional defect models in three to five seconds per specimen. Results show that mathematical regularization and spatio-temporal decoupling reduce spatial memorization in thermal-video depth regression.
Abstract:Accurate through-thickness measurement of subsurface delamination depth in Carbon Fiber Reinforced Polymer (CFRP) is important for structural assessment because defect location determines affected load-bearing layers. Optical pulsed thermography (OPT) provides a two-dimensional thermal video rather than volumetric measurements, so depth must be inferred from temporal heat-diffusion responses. A challenge is spatial dataset bias: when calibration defects follow regular grids, regression models may memorize their geometry instead of learning physical relationship between thermal decay and depth. This work introduces a spatio-temporal decoupling architecture that separates spatial defect localization from temporal depth measurement. Defect regions are first localized using segmentation methods, after which thermal responses are spatially averaged and converted into sixteen physics-informed temporal, energy, statistical, and geometric features. These features expose the one-dimensional heat-conduction relationship while withholding pixel coordinates from the depth model. Four regression models are evaluated using specimen-level cross-validation: Random Forest (RF), Gradient Boosting Machine (GBM), Advanced Multi-Layer Perceptron (Adv-MLP), and XGBoost. Unregularized trees and over-parameterized Adv-MLP exhibit calibration collapse under geometric shifts, with errors exceeding 0.5 mm. In contrast, regularized XGBoost with L1/L2 penalties and column sampling maintains cross-specimen calibration, achieving a mean absolute error (MAE) of 0.056 mm and root mean square error (RMSE) of 0.085 mm. Predicted depths are merged with masks to generate Delaunay-triangulated three-dimensional defect models in three to five seconds per specimen. Results show that mathematical regularization and spatio-temporal decoupling reduce spatial memorization in thermal-video depth regression.
Artificial Intelligence (cs.AI); Computer Vision and Pattern Recognition (cs.CV)
arXiv:2608.29223 [cs.AI]
(or arXiv:2608.29223v1 [cs.AI] for this version)
https://doi.org/10.48550/arXiv.2608.29223 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 334 words
Related coverage

Light Multiplication Unlocks Faster Quantum Computations
Quantum Zeitgeist · Jun 16, 2026

Runway’s WorldPrompt and the Engineering of Real-Time Worlds
Latent Space · Sep 25, 2026

Researchers Simulate Dirac Dynamics with Improved Time Steps
Quantum Zeitgeist · Sep 10, 2026

Informe de riesgos de la IA de frontera (febrero–marzo de 2026)
METR · May 19, 2026