aiqbench analysis
This study provides empirical evidence that transformer-based models face inherent compositional limits when answering complex clinical questions requiring multiple inferential steps in electronic health records. The findings demonstrate a consistent monotone decline in accuracy across different model architectures as reasoning depth increases, suggesting fundamental architectural constraints rather than data scarcity or context truncation are the primary failure modes.
Compositional Reasoning Depth Predicts Clinical AI Failure: Empirical Evidence Consistent with Transformer Compositionality Limits in Electronic Health Record Question Answering
arXiv:2606.16890v1 Announce Type: new Abstract: Aggregate accuracy benchmarks conceal a systematic structure in how large language models fail at electronic health record (EHR) question answering: questions requiring more inferential steps produce disproportionately more errors. Motivated by theoretical results on transformer compositionality limits, we introduce a pre-specified hop-count taxonomy -- the number of distinct reasoning steps required to answer a clinical question from an EHR -- as a principled predictor of model failure. We annotate 313 clinician-generated MedAlign EHR question-answer pairs across four hop levels and evaluate 301 questions in a within-model ablation (claude-sonnet-4-6, zero-shot vs. extended thinking) and cross-architecture replications (gpt-4o and gpt-5.4-2026-03-05, zero-shot). All three models, spanning two providers and two OpenAI generations (GPT-4 and GPT-5), show monotone accuracy decline with hop count: Claude Sonnet zero-shot falls from 30.6% (hop=1) to 17.6% (hop=4) (Cochran-Armitage z=-2.30, p=0.011; OR per hop 0.72, 95% CI [0.56,0.92], p=0.008); GPT-4o replicates this (37.8% to 14.7%; OR 0.58 [0.45,0.75], p<0.001); and gpt-5.4-2026-03-05 confirms it (37.8% to 23.5%; OR 0.80 [0.66,0.98], p=0.027). A pre-specified context-sufficiency audit shows higher-hop questions are not differentially disadvantaged by EHR truncation (answerability 93-95% at hops 2-4 vs. 79% at hop=1), so the decline reflects compositional reasoning difficulty. Extended thinking did not significantly flatten the accuracy-depth curve across three reasoning conditions, and thinking-token usage scaled with hop count (r=0.31, p<0.0001), consistent with the predicted O(k) computational requirement. Hop count is thus a theory-motivated, cross-architecture predictor of large-language-model error on EHR question answering, with direct implications for deployment risk stratification of clinical AI.
Abstract:Aggregate accuracy benchmarks conceal a systematic structure in how large language models fail at electronic health record (EHR) question answering: questions requiring more inferential steps produce disproportionately more errors. Motivated by theoretical results on transformer compositionality limits, we introduce a pre-specified hop-count taxonomy -- the number of distinct reasoning steps required to answer a clinical question from an EHR -- as a principled predictor of model failure. We annotate 313 clinician-generated MedAlign EHR question-answer pairs across four hop levels and evaluate 301 questions in a within-model ablation (claude-sonnet-4-6, zero-shot vs. extended thinking) and cross-architecture replications (gpt-4o and gpt-5.4-2026-03-05, zero-shot). All three models, spanning two providers and two OpenAI generations (GPT-4 and GPT-5), show monotone accuracy decline with hop count: Claude Sonnet zero-shot falls from 30.6% (hop=1) to 17.6% (hop=4) (Cochran-Armitage z=-2.30, p=0.011; OR per hop 0.72, 95% CI [0.56,0.92], p=0.008); GPT-4o replicates this (37.8% to 14.7%; OR 0.58 [0.45,0.75], p<0.001); and gpt-5.4-2026-03-05 confirms it (37.8% to 23.5%; OR 0.80 [0.66,0.98], p=0.027). A pre-specified context-sufficiency audit shows higher-hop questions are not differentially disadvantaged by EHR truncation (answerability 93-95% at hops 2-4 vs. 79% at hop=1), so the decline reflects compositional reasoning difficulty. Extended thinking did not significantly flatten the accuracy-depth curve across three reasoning conditions, and thinking-token usage scaled with hop count (r=0.31, p<0.0001), consistent with the predicted O(k) computational requirement. Hop count is thus a theory-motivated, cross-architecture predictor of large-language-model error on EHR question answering, with direct implications for deployment risk stratification of clinical AI.
20 pages, 5 figures. Code: this https URL
Computation and Language (cs.CL); Artificial Intelligence (cs.AI)
arXiv:2606.16890 [cs.CL]
(or arXiv:2606.16890v1 [cs.CL] for this version)
https://doi.org/10.48550/arXiv.2606.16890 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 351 words
Related coverage

PIRAMID: Progress and Plans
LessWrong · Jul 27, 2026
How to build a cancer vaccine, and whether they will work this time
LessWrong · Jun 8, 2026
Models Can't Remember Their Training. Neither Can You.
LessWrong · Jul 19, 2026
J++ Lens: Jacobian Filtering Enables More Faithful Workspace Lenses
LessWrong · Oct 8, 2026