aiqbench analysis
This study evaluates how different audio front-end processing techniques—specifically comparing standard log-mel spectrograms against PCEN normalization and multi-resolution stacks—affect the performance of a fixed Convolutional Neural Network for heart-sound classification. The results indicate that while all methods achieve high sensitivity, advanced preprocessing like PCEN yields marginal improvements in accuracy on the PhysioNet 2016 dataset without altering the core model architecture or training parameters. Furthermore, interpretability analysis via Grad-CAM confirms the models focus on physiologically relevant low-frequency components corresponding to S1 and S2 heart sounds rather than artifacts.
Comparing Spectrogram Front-Ends for Abnormal Heart-Sound Detection with a Convolutional Neural Network
arXiv:2607.16220v1 Announce Type: cross Abstract: Heart disease kills a lot of people, and one cheap way to catch it early is by listening to heart sounds with a stethoscope, or better yet, just recording them and running them through a model. This project is a binary classification task: take a short clip of someones heartbeat and decide if it sounds normal or abnormal. Instead of trying out a bunch of different models, we kept the CNN the same the whole time and just changed how we turned the raw audio into a picture for it to look at. We tried three ways of doing that: a regular logmel spectrogram, PCEN (which basically normalizes each frequency bin over time), and a multi resolution version that stacks a few different window sizes together. We ran all three on the PhysioNet 2016 heart-sound dataset with the exact same setup but same model, same optimizer, same random seed. Turns out all three do pretty well at catching abnormal cases (sensitivity around 0.95), but PCEN and multi-resolution both edge out the plain logmel on the official PhysioNet accuracy metric (0.915 and 0.916 vs. 0.910). We also ran Grad-CAM to see where the model was actually looking, and it mostly focused on the low frequencies where S1 and S2 heart sounds live, which is a good sign that it learned something real
Abstract:Heart disease kills a lot of people, and one cheap way to catch it early is by listening to heart sounds with a stethoscope, or better yet, just recording them and running them through a model. This project is a binary classification task: take a short clip of someones heartbeat and decide if it sounds normal or abnormal. Instead of trying out a bunch of different models, we kept the CNN the same the whole time and just changed how we turned the raw audio into a picture for it to look at. We tried three ways of doing that: a regular logmel spectrogram, PCEN (which basically normalizes each frequency bin over time), and a multi resolution version that stacks a few different window sizes together. We ran all three on the PhysioNet 2016 heart-sound dataset with the exact same setup but same model, same optimizer, same random seed. Turns out all three do pretty well at catching abnormal cases (sensitivity around 0.95), but PCEN and multi-resolution both edge out the plain logmel on the official PhysioNet accuracy metric (0.915 and 0.916 vs. 0.910). We also ran Grad-CAM to see where the model was actually looking, and it mostly focused on the low frequencies where S1 and S2 heart sounds live, which is a good sign that it learned something real
Computers and Society (cs.CY); Artificial Intelligence (cs.AI); Machine Learning (cs.LG); Sound (cs.SD); Audio and Speech Processing (eess.AS)
arXiv:2607.16220 [cs.CY]
(or arXiv:2607.16220v1 [cs.CY] for this version)
https://doi.org/10.48550/arXiv.2607.16220 Focus to learn more arXiv-issued DOI via DataCite
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 327 words
Related coverage

Underwriting Superintelligence: Backing Agents you can Sue — Rune Kvist, AIUC
Latent Space · Sep 16, 2026

The Apple Watch Series 12 is the start of a new wearable era
The Verge · Sep 17, 2026

The death of humanity
Fortune · Oct 16, 2026

[AINews] not much happened today
Latent Space · Oct 3, 2026