aiqbench analysis
This study evaluates how well state-of-the-art foundation models perform when applied to reduced sensor channels, specifically comparing EEG-only setups against ECG-only or combined configurations for sleep staging. The analysis reveals that while EEG carries the primary signal for sleep classification, certain architectures like BIOT maintain reasonable accuracy on wearable-compatible ECG data with a quantifiable performance drop. These findings are critical for researchers developing edge-cloud deployment strategies that balance model accuracy with the practical constraints of consumer wearable hardware.
Comparative Analysis of State-of-the-Art Foundation Models for Sleep Analysis Under Channel Reduction
arXiv:2609.22105v1 Announce Type: cross Abstract: Automatic sleep staging from polysomnography (PSG) is a well-studied task, but PSG itself is expensive, clinic-based, and burdensome to manually score, which limits its use for long-term or at-home monitoring. Most existing sleep-staging foundation models are evaluated using the full PSG montage. We instead ask how much of that montage is actually necessary. We evaluate six sleep staging models on the Multi-Ethnic Study of Atherosclerosis (MESA) PSG dataset across three signal conditions: electroencephalography (EEG), electrocardiography (ECG), and their combination (EEG+ECG). This is motivated by edge-cloud deployment, where EEG requires a clinic-grade scalp electrode, whereas ECG is already captured by consumer wearables. We test state-of-the-art foundation models such as SleepFM with an encoder trained from scratch on MESA, alongside BIOT, MOMENT, LaBraM, a base-scale Vision Transformer (ViT-B) reimplementation of SensorLM trained from scratch, and YASA, spanning EEG-pretrained, general-time-series, from-scratch, and classical non-learned approaches. No model architecture is modified from its original form; SensorLM's encoder is reimplemented only in PyTorch. For EEG-only staging, BIOT achieves the best result with a macro~F1 of 0.7237, followed by LaBraM (0.6835) and SleepFM from scratch (0.6582). Across the five models capable of ECG-only staging, switching from EEG to ECG costs between 0.2798 (MOMENT) and 0.4151 (BIOT) macro~F1, averaging 0.3531, while cutting the raw channel data rate to a third. Adding ECG to EEG provides no gain for most models. These results show that EEG carries most of the sleep-staging signal, quantify the consistent accuracy cost of the wearable-compatible alternative, and demonstrate that sleep-relevant pretraining transfers well to MESA.
Abstract:Automatic sleep staging from polysomnography (PSG) is a well-studied task, but PSG itself is expensive, clinic-based, and burdensome to manually score, which limits its use for long-term or at-home monitoring. Most existing sleep-staging foundation models are evaluated using the full PSG montage. We instead ask how much of that montage is actually necessary. We evaluate six sleep staging models on the Multi-Ethnic Study of Atherosclerosis (MESA) PSG dataset across three signal conditions: electroencephalography (EEG), electrocardiography (ECG), and their combination (EEG+ECG). This is motivated by edge-cloud deployment, where EEG requires a clinic-grade scalp electrode, whereas ECG is already captured by consumer wearables. We test state-of-the-art foundation models such as SleepFM with an encoder trained from scratch on MESA, alongside BIOT, MOMENT, LaBraM, a base-scale Vision Transformer (ViT-B) reimplementation of SensorLM trained from scratch, and YASA, spanning EEG-pretrained, general-time-series, from-scratch, and classical non-learned approaches. No model architecture is modified from its original form; SensorLM's encoder is reimplemented only in PyTorch. For EEG-only staging, BIOT achieves the best result with a macro~F1 of 0.7237, followed by LaBraM (0.6835) and SleepFM from scratch (0.6582). Across the five models capable of ECG-only staging, switching from EEG to ECG costs between 0.2798 (MOMENT) and 0.4151 (BIOT) macro~F1, averaging 0.3531, while cutting the raw channel data rate to a third. Adding ECG to EEG provides no gain for most models. These results show that EEG carries most of the sleep-staging signal, quantify the consistent accuracy cost of the wearable-compatible alternative, and demonstrate that sleep-relevant pretraining transfers well to MESA.
Signal Processing (eess.SP); Machine Learning (cs.LG)
arXiv:2609.22105 [eess.SP]
(or arXiv:2609.22105v1 [eess.SP] for this version)
https://doi.org/10.48550/arXiv.2609.22105 Focus to learn more arXiv-issued DOI via DataCite
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 347 words
Related coverage

Import AI 474: Platonic mindspace; TPUs in space; Zhipu starts an outer RSI loop
Import AI · Sep 28, 2026

News
Quantum Computing Report · Jun 7, 2026

News
Quantum Computing Report · Jul 25, 2026
HART: Hybrid Attention-RWKV Time series Foundation Model
arXiv · Oct 12, 2026