This research introduces CLSP-REQA, a framework that integrates real-time EEG quality assessment into seizure prediction pipelines using a Mamba-BiLSTM architecture. By modulating output confidence based on signal fidelity, the system addresses critical generalization gaps in cross-patient evaluations without requiring domain adaptation or additional target-patient data. The approach demonstrates significant performance gains on standard datasets while maintaining compatibility with closed-loop neurostimulator interfaces, offering a more robust path toward reliable clinical deployment.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

CLSP-REQA: A Real-Time Quality-Aware Closed-Loop Seizure Prediction Framework with Mamba-BiLSTM and Confidence-Gated Intervention

arXiv3 min read

arXiv:2606.00074v2 Announce Type: replace-cross Abstract: Reliable seizure prediction is a prerequisite for closed-loop neurostimulation therapy, yet existing methods rarely account for the variability in EEG signal quality encountered in real-world deployment, and the overwhelming majority adopt non-strict evaluation protocols that overestimate generalisation performance. We propose CLSP-REQA (Closed-Loop Seizure Prediction with Real-time EEG Quality Assessment), a unified framework that embeds a lightweight signal quality estimator directly within the prediction pipeline. A Real-time EEG Quality Assessment (REQA) module runs in parallel with a Mamba-BiLSTM backbone, producing a scalar quality score q in [0,1] that modulates output confidence through a tiered non-linear fusion function (ECLO). Under strict cross-patient evaluation on the CHB-MIT Scalp EEG Database (n = 23 subjects, 198 seizures), CLSP-REQA achieves an AUC-ROC of 0.7426 +- 0.0199, outperforming the unadapted cross-patient baseline of 0.69 reported by Jemal et al., using only 16 EEG channels compared to 23 in prior work, and without requiring any target-patient data or domain adaptation. On the SIENA Scalp EEG Database (n = 14 subjects, 47 seizures), CLSP-REQA achieves AUC 0.7012 +- 0.0249, substantially surpassing the best domain-adapted cross-patient result of 0.61 on the same dataset, demonstrating strong cross-dataset generalisation. The framework outputs a structured four-tuple (p, q, c, Phi_SHAP) directly compatible with closed-loop neurostimulator interfaces.

Abstract:Reliable seizure prediction is a prerequisite for closed-loop neurostimulation therapy, yet existing methods rarely account for the variability in EEG signal quality encountered in real-world deployment, and the overwhelming majority adopt non-strict evaluation protocols that overestimate generalisation performance. We propose CLSP-REQA (Closed-Loop Seizure Prediction with Real-time EEG Quality Assessment), a unified framework that embeds a lightweight signal quality estimator directly within the prediction pipeline. A Real-time EEG Quality Assessment (REQA) module runs in parallel with a Mamba-BiLSTM backbone, producing a scalar quality score q in [0,1] that modulates output confidence through a tiered non-linear fusion function (ECLO). Under strict cross-patient evaluation on the CHB-MIT Scalp EEG Database (n = 23 subjects, 198 seizures), CLSP-REQA achieves an AUC-ROC of 0.7426 +- 0.0199, outperforming the unadapted cross-patient baseline of 0.69 reported by Jemal et al., using only 16 EEG channels compared to 23 in prior work, and without requiring any target-patient data or domain adaptation. On the SIENA Scalp EEG Database (n = 14 subjects, 47 seizures), CLSP-REQA achieves AUC 0.7012 +- 0.0249, substantially surpassing the best domain-adapted cross-patient result of 0.61 on the same dataset, demonstrating strong cross-dataset generalisation. The framework outputs a structured four-tuple (p, q, c, Phi_SHAP) directly compatible with closed-loop neurostimulator interfaces.

Signal Processing (eess.SP); Artificial Intelligence (cs.AI); Machine Learning (cs.LG)

arXiv:2606.00074 [eess.SP]

(or arXiv:2606.00074v2 [eess.SP] for this version)

https://doi.org/10.48550/arXiv.2606.00074 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.