aiqbench analysis
This research introduces CineMR, a tool-augmented vision-language model that significantly improves quantitative cardiac MRI assessment by integrating external analysis tools into its reasoning process. By employing Group Relative Policy Optimization to refine tool invocation, the system achieves substantial accuracy gains in extracting ventricular metrics compared to standard backbone models without such integration. The study underscores the critical necessity of reliable tool use for medical AI to handle complex, multidimensional imaging tasks effectively.
CineMR: Tool-Integrated Vision-Language Reasoning for Quantitative Cardiac MRI Assessment
arXiv:2610.01166v1 Announce Type: cross Abstract: Cardiovascular magnetic resonance (CMR), including cine imaging, is a reference standard for the noninvasive assessment of cardiac morphology and ventricular function. Cine CMR interpretation integrates qualitative visual assessment with quantitative measurements of ventricular volumes, ejection fraction, myocardial mass, wall thickness, and regional wall motion. Current medical vision-language models (VLMs) cannot reliably derive quantitative measurements from multidimensional cine images without analysis tools. We present CineMR, a tool-augmented VLM that invokes cardiac image-analysis tools and integrates their outputs into interleaved reasoning for quantitative CMR assessment. We also construct a multi-cohort visual question answering benchmark covering quantitative metric extraction, multiclass diagnosis, and differential diagnosis, together with tools for segmentation, phase selection, volumetry, morphometry, and regional wall motion analysis. CineMR is trained with supervised fine-tuning (SFT) on tool-interaction traces followed by Group Relative Policy Optimization (GRPO) with conditional tool-use rewards. On the multi-cohort cine CMR benchmark, CineMR achieves 35.9% pass@1 and 58.9% pass@4, compared with 1.5% pass@1 for the Qwen3-VL-8B backbone and 0.0% and 7.0% pass@1 for LLaVA-Med v1.5 and MedGemma-4B, respectively. Correct tool invocation reaches 99.8% after GRPO, up from 78.9% after SFT. Live tool outputs improve ventricular measurement accuracy by 20.4--23.7% over direct model predictions, and removing all tools reduces pass@1 from 35.9% to 27.9%. These results highlight the importance of reliable tool use for quantitative cine CMR reasoning and support CineMR as a promising approach for assistive cardiac image assessment. Code, benchmark resources, and model weights are available at https://github.com/AI-MIND-Lab/CineMR.
Abstract:Cardiovascular magnetic resonance (CMR), including cine imaging, is a reference standard for the noninvasive assessment of cardiac morphology and ventricular function. Cine CMR interpretation integrates qualitative visual assessment with quantitative measurements of ventricular volumes, ejection fraction, myocardial mass, wall thickness, and regional wall motion. Current medical vision-language models (VLMs) cannot reliably derive quantitative measurements from multidimensional cine images without analysis tools. We present CineMR, a tool-augmented VLM that invokes cardiac image-analysis tools and integrates their outputs into interleaved reasoning for quantitative CMR assessment. We also construct a multi-cohort visual question answering benchmark covering quantitative metric extraction, multiclass diagnosis, and differential diagnosis, together with tools for segmentation, phase selection, volumetry, morphometry, and regional wall motion analysis. CineMR is trained with supervised fine-tuning (SFT) on tool-interaction traces followed by Group Relative Policy Optimization (GRPO) with conditional tool-use rewards. On the multi-cohort cine CMR benchmark, CineMR achieves 35.9% pass@1 and 58.9% pass@4, compared with 1.5% pass@1 for the Qwen3-VL-8B backbone and 0.0% and 7.0% pass@1 for LLaVA-Med v1.5 and MedGemma-4B, respectively. Correct tool invocation reaches 99.8% after GRPO, up from 78.9% after SFT. Live tool outputs improve ventricular measurement accuracy by 20.4--23.7% over direct model predictions, and removing all tools reduces pass@1 from 35.9% to 27.9%. These results highlight the importance of reliable tool use for quantitative cine CMR reasoning and support CineMR as a promising approach for assistive cardiac image assessment. Code, benchmark resources, and model weights are available at this https URL.
Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)
arXiv:2610.01166 [cs.CV]
(or arXiv:2610.01166v1 [cs.CV] for this version)
https://doi.org/10.48550/arXiv.2610.01166 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 341 words
Related coverage

Introducing CARE-X: Towards Clinically Useful Radiology VLMs with Auxiliary Supervision, Reward-Aligned Learning, and Tool-Augmented Measurement
Microsoft Research · Aug 11, 2026

[AINews] The Future of Latent Space
Latent Space · Sep 25, 2026

[AINews] Opus 5.5 is good at explainer videos
Latent Space · Sep 29, 2026

AGI Safety and Alignment at Google DeepMind: A Summary of Recent Work (July 2026)
AI Alignment Forum · Jul 31, 2026