Skip to content
aiqbench takeAI Research

aiqbench analysis

This research introduces CHI, a novel metric that unifies the evaluation of entity, relation, and quantity hallucinations in AI-generated summaries into a single composite score. By statistically validating these dimensions as orthogonal, the study offers a more robust method for assessing faithfulness than existing baselines like ROUGE, directly addressing a critical gap in LLM reliability assessment.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

CHI: A Composite Hallucination Index Unifying Entity, Relation, and Quantity Dimensions for Summarization Evaluation

arXiv3 min read

arXiv:2609.33343v1 Announce Type: new Abstract: Faithfulness evaluation of abstractive summaries remains an open challenge, with existing metrics addressing only isolated hallucination types: factual entity errors, relational inconsistencies, or numerical fabrications, without capturing their co-occurrence or interaction. We introduce CHI (Composite Hallucination Index), the first unified hallucination metric that decomposes faithfulness errors into three orthogonal dimensions: entity hallucination (EHI), relation hallucination (RHI*), and quantity hallucination (QHI). Each dimension employs a shared softmax-normalized architecture over Venn diagram-derived factors representing extractiveness, positive hallucination, over-focus, negative hallucination, and lost focus. The novel QHI component introduces tolerance-aware numerical matching with exact, epsilon, derived, and temporal comparison modes. We fuse the three dimensions via harmonic mean to produce a single composite score that penalizes weakness in any dimension. We validate CHI on 800 source articles spanning four domains (news, medical, legal, financial) with summaries from five generation systems. Empirical results demonstrate that: (i) the three dimensions are statistically orthogonal (mean rho = 0.148), confirming they capture distinct error types; (ii) CHI achieves the highest system-level correlation with human judgments (rho = 0.66, p = 0.006) on SummEval, outperforming ROUGE (rho = 0.53), EHI (rho = 0.58), and all individual components; and (iii) ablation studies confirm that all three dimensions contribute unique variance, with the full composite outperforming any individual component while providing decomposable error diagnostics unavailable from single-score baselines. CHI provides practitioners with a decomposable, interpretable, and efficient faithfulness metric suitable for both offline evaluation and online monitoring of summarization systems.

Abstract:Faithfulness evaluation of abstractive summaries remains an open challenge, with existing metrics addressing only isolated hallucination types: factual entity errors, relational inconsistencies, or numerical fabrications, without capturing their co-occurrence or interaction. We introduce CHI (Composite Hallucination Index), the first unified hallucination metric that decomposes faithfulness errors into three orthogonal dimensions: entity hallucination (EHI), relation hallucination (RHI*), and quantity hallucination (QHI). Each dimension employs a shared softmax-normalized architecture over Venn diagram-derived factors representing extractiveness, positive hallucination, over-focus, negative hallucination, and lost focus. The novel QHI component introduces tolerance-aware numerical matching with exact, epsilon, derived, and temporal comparison modes. We fuse the three dimensions via harmonic mean to produce a single composite score that penalizes weakness in any dimension. We validate CHI on 800 source articles spanning four domains (news, medical, legal, financial) with summaries from five generation systems. Empirical results demonstrate that: (i) the three dimensions are statistically orthogonal (mean rho = 0.148), confirming they capture distinct error types; (ii) CHI achieves the highest system-level correlation with human judgments (rho = 0.66, p = 0.006) on SummEval, outperforming ROUGE (rho = 0.53), EHI (rho = 0.58), and all individual components; and (iii) ablation studies confirm that all three dimensions contribute unique variance, with the full composite outperforming any individual component while providing decomposable error diagnostics unavailable from single-score baselines. CHI provides practitioners with a decomposable, interpretable, and efficient faithfulness metric suitable for both offline evaluation and online monitoring of summarization systems.

Computation and Language (cs.CL); Artificial Intelligence (cs.AI)

arXiv:2609.33343 [cs.CL]

(or arXiv:2609.33343v1 [cs.CL] for this version)

https://doi.org/10.48550/arXiv.2609.33343 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 338 words

Related coverage