Skip to content
aiqbench takeAI Research

aiqbench analysis

This research bridges the semantic strength of CLIP with the spatial precision of Vision Foundation Models to solve few-shot anomaly detection in medical imaging. By injecting structural priors into visual embeddings, the proposed framework significantly improves lesion localization and segmentation accuracy across multiple modalities like CT and MRI. The approach offers a practical pathway for deploying robust AI diagnostics where labeled data is scarce.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Bridging Vision Foundation Model Priors with CLIP for Spatial-aware Few-shot Anomaly Detection in Medical Images

arXiv3 min read

arXiv:2609.12454v1 Announce Type: cross Abstract: Vision-Language Models such as CLIP enable effective few-shot medical anomaly detection (AD) via strong image-text semantic alignment. However, their globally contrastive pretraining lacks explicit spatial supervision, limiting precise lesion localization. In contrast, Vision Foundation Models (VFMs) such as DINO learn spatially coherent patch representations via self-distillation and local-to-global consistency, better capturing fine-grained anatomical structures. Leveraging this complementarity, we propose Spatial-FAD, a spatial-aware few-shot medical AD framework that improves lesion localization by combining VFM spatial priors with CLIP semantics. Specifically, we introduce a VFM-enhanced adapter that injects a structural affinity prior derived from DINO into CLIP features. This structure-guided refinement encourages visual embeddings to better adhere to lesion boundaries while maintaining semantic alignment. To address the loss of spatial detail from patchification and the limited input resolution of CLIP, we adopt a sliding-window aggregation strategy. This generates high-resolution, spatially dense embeddings to further enhance localization granularity. Moreover, we introduce a prototype-enhanced support memory scheme to efficiently exploit the few-shot support set. This module stores compact prototypes for normal and abnormal patterns, reducing memory costs while boosting performance by fusing patch-to-prototype and image-text similarities. Extensive experiments on three benchmark datasets, including Liver CT, Retinal OCT, and Brain MRI, demonstrate that Spatial-FAD significantly outperforms state-of-the-art methods, especially in lesion segmentation. Notably, in the 4-shot scenario, our method achieves an average improvement of over 11.4% in Dice score and 1.8% in AUC. Code is available at: https://github.com/JuzhengMiao/Spatial-FAD.

Abstract:Vision-Language Models such as CLIP enable effective few-shot medical anomaly detection (AD) via strong image-text semantic alignment. However, their globally contrastive pretraining lacks explicit spatial supervision, limiting precise lesion localization. In contrast, Vision Foundation Models (VFMs) such as DINO learn spatially coherent patch representations via self-distillation and local-to-global consistency, better capturing fine-grained anatomical structures. Leveraging this complementarity, we propose Spatial-FAD, a spatial-aware few-shot medical AD framework that improves lesion localization by combining VFM spatial priors with CLIP semantics. Specifically, we introduce a VFM-enhanced adapter that injects a structural affinity prior derived from DINO into CLIP features. This structure-guided refinement encourages visual embeddings to better adhere to lesion boundaries while maintaining semantic alignment. To address the loss of spatial detail from patchification and the limited input resolution of CLIP, we adopt a sliding-window aggregation strategy. This generates high-resolution, spatially dense embeddings to further enhance localization granularity. Moreover, we introduce a prototype-enhanced support memory scheme to efficiently exploit the few-shot support set. This module stores compact prototypes for normal and abnormal patterns, reducing memory costs while boosting performance by fusing patch-to-prototype and image-text similarities. Extensive experiments on three benchmark datasets, including Liver CT, Retinal OCT, and Brain MRI, demonstrate that Spatial-FAD significantly outperforms state-of-the-art methods, especially in lesion segmentation. Notably, in the 4-shot scenario, our method achieves an average improvement of over 11.4% in Dice score and 1.8% in AUC. Code is available at: this https URL.

Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI); Machine Learning (cs.LG)

arXiv:2609.12454 [cs.CV]

(or arXiv:2609.12454v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2609.12454 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 338 words

Related coverage