Skip to content
aiqbench takeAI Research

aiqbench analysis

This research introduces DB-SUiT, a surface-based diffusion model that translates MRI scans into synthetic PET images while preserving the complex geometry of the folded cortex. By leveraging spherical convolutions and bottleneck Transformers, the framework achieves diagnostic accuracy in dementia classification that nearly matches real PET data without requiring retraining on new cohorts. This advancement offers a promising pathway to reduce reliance on costly and radiation-exposed PET scans for neurological disease screening.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Bridging Modalities on the Cortex: Surface-based MRI to PET Translation with a Diffusion Bridge

arXiv3 min read

arXiv:2609.20147v1 Announce Type: cross Abstract: Cortical hypometabolism measured by Fluorodeoxyglucose Positron Emission Tomography (FDG-PET) is a highly sensitive biomarker for dementia diagnosis. However, high costs, radiation exposure, and limited accessibility constrain its clinical utility. While cross-modal synthesis from Magnetic Resonance Imaging (MRI) offers a promising alternative, existing volumetric generation methods do not explicitly account for the highly folded cortical geometry, where disease-related patterns predominantly reside. To address this, we introduce a novel surface-based diffusion bridge framework DB-SUiT for MRI-to-PET translation that operates natively on the cortical manifold. A conditional Spherical U-shaped vision Transformer (SUiT) is specifically designed to model the intricate cross-modal relationships while preserving surface topology. It combines spherical convolutional encoders for multi-scale surface feature extraction with bottleneck Transformers to capture long-range spatial dependencies, while incorporating demographic and subcortical conditions to refine the synthesis. Evaluated on two datasets, including subjects with different dementia types, DB-SUiT demonstrates high-fidelity synthesis that substantially outperforms other baselines. In automated dementia classification, synthesized PET surfaces improve performance over MRI by 14.2% and PET volumes by 11.3%, approaching the performance of real PET surfaces. In a blinded reader study, synthetic PET achieved 85.5% diagnostic accuracy, compared with 75.8% for MRI and 95.2% for real PET. This further demonstrates cross-cohort and cross-pathology generalization, as the model was evaluated without retraining on an external cohort that included a dementia subtype not represented during training. Our code is available at https://github.com/ai-med/DB-SUiT.

Abstract:Cortical hypometabolism measured by Fluorodeoxyglucose Positron Emission Tomography (FDG-PET) is a highly sensitive biomarker for dementia diagnosis. However, high costs, radiation exposure, and limited accessibility constrain its clinical utility. While cross-modal synthesis from Magnetic Resonance Imaging (MRI) offers a promising alternative, existing volumetric generation methods do not explicitly account for the highly folded cortical geometry, where disease-related patterns predominantly reside. To address this, we introduce a novel surface-based diffusion bridge framework DB-SUiT for MRI-to-PET translation that operates natively on the cortical manifold. A conditional Spherical U-shaped vision Transformer (SUiT) is specifically designed to model the intricate cross-modal relationships while preserving surface topology. It combines spherical convolutional encoders for multi-scale surface feature extraction with bottleneck Transformers to capture long-range spatial dependencies, while incorporating demographic and subcortical conditions to refine the synthesis. Evaluated on two datasets, including subjects with different dementia types, DB-SUiT demonstrates high-fidelity synthesis that substantially outperforms other baselines. In automated dementia classification, synthesized PET surfaces improve performance over MRI by 14.2% and PET volumes by 11.3%, approaching the performance of real PET surfaces. In a blinded reader study, synthetic PET achieved 85.5% diagnostic accuracy, compared with 75.8% for MRI and 95.2% for real PET. This further demonstrates cross-cohort and cross-pathology generalization, as the model was evaluated without retraining on an external cohort that included a dementia subtype not represented during training. Our code is available at this https URL.

Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)

arXiv:2609.20147 [cs.CV]

(or arXiv:2609.20147v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2609.20147 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 330 words

Related coverage