This research introduces RABR-Net, a framework that enhances biomedical image segmentation by explicitly modeling uncertainty to refine ambiguous boundaries rather than just maximizing global overlap metrics. By combining entropy and variance signals with a gated residual refiner, the method achieves measurable improvements in boundary precision and robustness against perturbations without sacrificing overall classification accuracy. The work addresses a critical gap in clinical AI applications where confidence calibration near object edges is as vital as segmentation completeness.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Beyond Accuracy: Uncertainty-Guided Boundary Refinement for Reliable Biomedical Image Segmentation

arXiv3 min read

arXiv:2609.12892v1 Announce Type: cross Abstract: Accurate biomedical image segmentation requires not only high global overlap but also reliable delineation of clinically meaningful boundaries. In blood-smear microscopy, cytoplasm and nucleus contours provide the structural basis for downstream morphology analysis; however, deep segmentation models may remain uncertain or overconfident near ambiguous boundary regions even when achieving strong Dice scores. This work proposes a Reliability-Aware Boundary Refinement Network (RABR-Net), a two-stage framework for trustworthy image segmentation. A strong UNet++ EfficientNet-B4 base segmenter first produces initial class probabilities and logits. Predictive entropy, test-time augmentation variance, margin uncertainty, probability gradients, and soft boundary cues are then combined into a boundary-aware reliability representation. This representation guides a gated residual refiner that selectively corrects uncertain boundary pixels while preserving confident regions of the base prediction. The framework is evaluated using overlap accuracy, class-wise Dice, Boundary Dice, HD95/ASSD, calibration, risk--coverage analysis, robustness under image perturbations, qualitative correction maps, and paired statistical testing. On the held-out test set, the proposed method improves Dice from 0.9602 to 0.9614, Boundary Dice from 0.3448 to 0.3611, and HD95 from 3.0354 to 2.8274 compared with the cached base prediction. Statistical analysis confirms significant improvements in Dice, Boundary Dice, and HD95. Qualitative results show that the learned gate concentrates around uncertain cytoplasm and nucleus boundaries, and correction maps confirm localized boundary refinement. Although calibration does not automatically improve after refinement, the proposed framework provides an interpretable and reliability-focused strategy for boundary-sensitive biomedical image segmentation.

Abstract:Accurate biomedical image segmentation requires not only high global overlap but also reliable delineation of clinically meaningful boundaries. In blood-smear microscopy, cytoplasm and nucleus contours provide the structural basis for downstream morphology analysis; however, deep segmentation models may remain uncertain or overconfident near ambiguous boundary regions even when achieving strong Dice scores. This work proposes a Reliability-Aware Boundary Refinement Network (RABR-Net), a two-stage framework for trustworthy image segmentation. A strong UNet++ EfficientNet-B4 base segmenter first produces initial class probabilities and logits. Predictive entropy, test-time augmentation variance, margin uncertainty, probability gradients, and soft boundary cues are then combined into a boundary-aware reliability representation. This representation guides a gated residual refiner that selectively corrects uncertain boundary pixels while preserving confident regions of the base prediction. The framework is evaluated using overlap accuracy, class-wise Dice, Boundary Dice, HD95/ASSD, calibration, risk--coverage analysis, robustness under image perturbations, qualitative correction maps, and paired statistical testing. On the held-out test set, the proposed method improves Dice from 0.9602 to 0.9614, Boundary Dice from 0.3448 to 0.3611, and HD95 from 3.0354 to 2.8274 compared with the cached base prediction. Statistical analysis confirms significant improvements in Dice, Boundary Dice, and HD95. Qualitative results show that the learned gate concentrates around uncertain cytoplasm and nucleus boundaries, and correction maps confirm localized boundary refinement. Although calibration does not automatically improve after refinement, the proposed framework provides an interpretable and reliability-focused strategy for boundary-sensitive biomedical image segmentation.

Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG)

arXiv:2609.12892 [cs.CV]

(or arXiv:2609.12892v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2609.12892 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 335 words