aiqbench analysis
This research introduces a fully automatic pipeline for camera intrinsic calibration, eliminating the need for manual image filtering or distortion order selection in robot perception systems. By employing an iterative rejection scheme and validating distortion orders on held-out data, the method significantly reduces reprojection error compared to existing configurations. The release of associated code and datasets will likely accelerate practical deployments in autonomous robotics that rely on high-fidelity visual input.
Automatic Reproducible Camera Intrinsic Calibration
arXiv:2609.10082v1 Announce Type: new Abstract: Accurate camera intrinsic calibration is fundamental to robot perception, and the accuracy depends on the quality of the collected images. However, existing target-based calibration methods often require the practitioner to manually filter out high-quality images and to specify an appropriate radial distortion order. This paper presents a fully automatic intrinsic calibration pipeline that determines both from the collected data. We adopt an iterative rejection scheme that estimates parameters on a candidate image set and removes views whose mean residual exceeds a multiple of the median. Crucially, this process runs independently under each candidate distortion order, so that the retained image set is consistent with the residual scale of that order. Further, the distortion order is selected on held-out images, with the intrinsics and distortion fixed and only the board pose re-estimated, ensuring that an added coefficient is supported by independent observations. Finally, we integrate both steps into an interactive calibration tool that supports full-pipeline data inspection and parameter estimation. Experiments on our own camera data and five public real-world datasets show that image filtering reduces the held-out reprojection error by 25\%, the order selection further by 5\%, achieving the lowest held-out mean among four compared configurations without manual image selection. We will release the code and data to facilitate future research.
Abstract:Accurate camera intrinsic calibration is fundamental to robot perception, and the accuracy depends on the quality of the collected images. However, existing target-based calibration methods often require the practitioner to manually filter out high-quality images and to specify an appropriate radial distortion order. This paper presents a fully automatic intrinsic calibration pipeline that determines both from the collected data. We adopt an iterative rejection scheme that estimates parameters on a candidate image set and removes views whose mean residual exceeds a multiple of the median. Crucially, this process runs independently under each candidate distortion order, so that the retained image set is consistent with the residual scale of that order. Further, the distortion order is selected on held-out images, with the intrinsics and distortion fixed and only the board pose re-estimated, ensuring that an added coefficient is supported by independent observations. Finally, we integrate both steps into an interactive calibration tool that supports full-pipeline data inspection and parameter estimation. Experiments on our own camera data and five public real-world datasets show that image filtering reduces the held-out reprojection error by 25\%, the order selection further by 5\%, achieving the lowest held-out mean among four compared configurations without manual image selection. We will release the code and data to facilitate future research.
Robotics (cs.RO); Computer Vision and Pattern Recognition (cs.CV)
arXiv:2609.10082 [cs.RO]
(or arXiv:2609.10082v1 [cs.RO] for this version)
https://doi.org/10.48550/arXiv.2609.10082 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 310 words
Related coverage

Build a Multi-Camera 3D Tracking Application with NVIDIA DeepStream 9.1 Skills
NVIDIA · Jul 15, 2026

NVIDIA Released DeepStream 9.1: Bringing Agentic AI to Vision AI With 13 Skills and Multi-View 3D Tracking
MarkTechPost · Jul 18, 2026
LV-Calib: LiDAR-Camera Extrinsic Calibration with Boundary-Response Modeling
arXiv · Jun 16, 2026
DiffPhysCam: Differentiable Physics-Based Camera Simulation for Inverse Rendering and Embodied AI
arXiv · Aug 4, 2026