This study applies a Fast Fourier Convolution ResNet (FFCResNet) to ECG analysis, marking the primary subject as AI/ML within healthcare diagnostics rather than general medical news or consumer tech. The research focuses on rigorous statistical validation of an end-to-end machine learning pipeline for cardiac interval measurement across large-scale clinical datasets.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Automated ECG Interval Measurement and Wave Delineation Using Fast Fourier Convolution ResNet

arXiv3 min read

arXiv:2608.00058v1 Announce Type: cross Abstract: Accurate measurement of ECG intervals, including PR, QRS duration, and QT/QTc, is central to cardiac diagnosis, yet the published ECG delineation literature evaluates performance almost exclusively as fiducial-point timing errors on small curated databases, rather than as clinical interval accuracy on large unselected cohorts. We bridge this gap by evaluating a complete end-to-end pipeline on 10,646 clinical 12-lead ECGs and reporting the first large-scale interval measurement accuracy study with full statistical characterisation, including bias, 95% limits of agreement (Bland-Altman), bootstrap confidence intervals, and rhythm-stratified error analysis. The underlying delineation is performed by a Fast Fourier Convolution ResNet (FFCResNet), adapting local temporal convolutions with global spectral processing via FFT and augmented with register tokens for contextual feature learning. Three per-wave models (P, QRS, and T) are trained on six public databases with ECG-specific augmentation. On 10,646 ECGs, the system achieves a QT MAE of 17.5 ms [95% CI: 16.9-18.2], with a Bland-Altman bias of +8.5 ms (LoA: -68.5 to +85.5 ms); a QRS duration MAE of 14.8 ms [95% CI: 14.6-15.0], with a bias of +12.6 ms (LoA: -12.3 to +37.6 ms); and a ventricular rate MAE of 0.8 beats/min. All biases are statistically significant by the Wilcoxon signed-rank test (p < 0.001) but remain within or near published inter-observer variability bounds for sinus rhythms. Rhythm-stratified analysis reveals substantially higher QT errors for supraventricular tachycardias (SVT MAE: 75.0 ms; AVRT MAE: 85.3 ms) than for sinus bradycardia (SB MAE: 9.3 ms) and sinus rhythm (SR MAE: 8.9 ms), providing an honest characterisation of the deployment scope. Wave segmentation achieves internal Dice scores of 95.5%, 98.2%, and 96.1% for P, QRS, and T waves, respectively, and cross-database Dice scores of 78.1%, 85.5%, and 74.2%.

Abstract:Accurate measurement of ECG intervals, including PR, QRS duration, and QT/QTc, is central to cardiac diagnosis, yet the published ECG delineation literature evaluates performance almost exclusively as fiducial-point timing errors on small curated databases, rather than as clinical interval accuracy on large unselected cohorts. We bridge this gap by evaluating a complete end-to-end pipeline on 10,646 clinical 12-lead ECGs and reporting the first large-scale interval measurement accuracy study with full statistical characterisation, including bias, 95% limits of agreement (Bland-Altman), bootstrap confidence intervals, and rhythm-stratified error analysis. The underlying delineation is performed by a Fast Fourier Convolution ResNet (FFCResNet), adapting local temporal convolutions with global spectral processing via FFT and augmented with register tokens for contextual feature learning. Three per-wave models (P, QRS, and T) are trained on six public databases with ECG-specific augmentation. On 10,646 ECGs, the system achieves a QT MAE of 17.5 ms [95% CI: 16.9-18.2], with a Bland-Altman bias of +8.5 ms (LoA: -68.5 to +85.5 ms); a QRS duration MAE of 14.8 ms [95% CI: 14.6-15.0], with a bias of +12.6 ms (LoA: -12.3 to +37.6 ms); and a ventricular rate MAE of 0.8 beats/min. All biases are statistically significant by the Wilcoxon signed-rank test (p < 0.001) but remain within or near published inter-observer variability bounds for sinus rhythms. Rhythm-stratified analysis reveals substantially higher QT errors for supraventricular tachycardias (SVT MAE: 75.0 ms; AVRT MAE: 85.3 ms) than for sinus bradycardia (SB MAE: 9.3 ms) and sinus rhythm (SR MAE: 8.9 ms), providing an honest characterisation of the deployment scope. Wave segmentation achieves internal Dice scores of 95.5%, 98.2%, and 96.1% for P, QRS, and T waves, respectively, and cross-database Dice scores of 78.1%, 85.5%, and 74.2%.

11 pages, 5 figures, and 7 tables. Includes large-scale evaluation on 10,646 12-lead ECGs

Signal Processing (eess.SP); Artificial Intelligence (cs.AI); Machine Learning (cs.LG)

I.2.6; I.5.4; J.3

arXiv:2608.00058 [eess.SP]

(or arXiv:2608.00058v1 [eess.SP] for this version)

https://doi.org/10.48550/arXiv.2608.00058 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 397 words