This research proposes a hybrid 2D-3D CNN framework to mitigate artifacts in undersampled cone-beam CT scans, directly applying deep learning techniques to improve medical imaging fidelity. By leveraging slice-wise feature extraction followed by volumetric decoding, the method balances computational efficiency with high-quality 3D reconstruction for diagnostic utility. The work represents a significant advancement in using AI to optimize radiation-reduced imaging protocols without compromising image integrity.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Artifact Reduction in Undersampled 3D Cone-Beam CTs using a Hybrid 2D-3D CNN Framework

arXiv2 min read

arXiv:2602.08727v2 Announce Type: replace-cross Abstract: Undersampled CT volumes minimize acquisition time and radiation exposure but introduce artifacts degrading image quality and diagnostic utility. Reducing these artifacts is critical for high-quality imaging. We propose a computationally efficient hybrid deep-learning framework that combines the strengths of 2D and 3D models. First, a 2D U-Net operates on individual slices of undersampled CT volumes to extract feature maps. These slice-wise feature maps are then stacked across the volume and used as input to a 3D decoder, which utilizes contextual information across slices to predict an artifact-free 3D CT volume. The proposed two-stage approach balances the computational efficiency of 2D processing with the volumetric consistency provided by 3D modeling. The results show substantial improvements in inter-slice consistency in coronal and sagittal direction with low computational overhead. This hybrid framework presents a robust and efficient solution for high-quality 3D CT image post-processing. The code of this project can be found on github: https://github.com/J-3TO/2D-3DCNN_sparseview/.

Abstract:Undersampled CT volumes minimize acquisition time and radiation exposure but introduce artifacts degrading image quality and diagnostic utility. Reducing these artifacts is critical for high-quality imaging. We propose a computationally efficient hybrid deep-learning framework that combines the strengths of 2D and 3D models. First, a 2D U-Net operates on individual slices of undersampled CT volumes to extract feature maps. These slice-wise feature maps are then stacked across the volume and used as input to a 3D decoder, which utilizes contextual information across slices to predict an artifact-free 3D CT volume. The proposed two-stage approach balances the computational efficiency of 2D processing with the volumetric consistency provided by 3D modeling. The results show substantial improvements in inter-slice consistency in coronal and sagittal direction with low computational overhead. This hybrid framework presents a robust and efficient solution for high-quality 3D CT image post-processing. The code of this project can be found on github: this https URL.

Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)

arXiv:2602.08727 [cs.CV]

(or arXiv:2602.08727v2 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2602.08727 Focus to learn more arXiv-issued DOI via DataCite

https://doi.org/10.1109/NSS/MIC/RTSD57106.2025.11287452 Focus to learn more DOI(s) linking to related resources

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 262 words

Related coverage