Off-topic for aiqbench
This story was gathered from a source we follow but falls outside AI and quantum coverage, so there is no aiqbench take for it.
AnchorHEC: Targetless Hand-Eye Calibration of Wrist and Fixed Cameras
arXiv:2611.02884v1 Announce Type: new Abstract: Recent robot systems combine wrist and fixed cameras, requiring camera-to-robot transforms for both. Most hand-eye calibration methods rely on targets or robot-body observations. Scene-based methods using 3D reconstruction require neither but address only wrist cameras. We introduce AnchorHEC, a targetless hand-eye calibration framework for wrist and fixed cameras in a single procedure using RGB images, forward kinematics (FK), and known camera intrinsics. We initialize both camera types using FK and a shared 3D foundation model reconstruction. FK-constrained wrist-image bundle adjustment reduces the impact of reconstructed pose and scale errors. If this refinement fails or retains too few inliers, we relax the constraints on potentially inaccurate FK poses and lens parameters. We use the refined wrist transform and FK to triangulate metric points and estimate fixed-camera poses. Across three backbones, calibration errors in simulation decrease by 86.4% in translation and 71.6% in rotation, averaged over both camera types, relative to reconstruction-based baselines. We also validate AnchorHEC on a physical robot. Project page: https://hwanggb.github.io/AnchorHEC/
Abstract:Recent robot systems combine wrist and fixed cameras, requiring camera-to-robot transforms for both. Most hand-eye calibration methods rely on targets or robot-body observations. Scene-based methods using 3D reconstruction require neither but address only wrist cameras. We introduce AnchorHEC, a targetless hand-eye calibration framework for wrist and fixed cameras in a single procedure using RGB images, forward kinematics (FK), and known camera intrinsics. We initialize both camera types using FK and a shared 3D foundation model reconstruction. FK-constrained wrist-image bundle adjustment reduces the impact of reconstructed pose and scale errors. If this refinement fails or retains too few inliers, we relax the constraints on potentially inaccurate FK poses and lens parameters. We use the refined wrist transform and FK to triangulate metric points and estimate fixed-camera poses. Across three backbones, calibration errors in simulation decrease by 86.4% in translation and 71.6% in rotation, averaged over both camera types, relative to reconstruction-based baselines. We also validate AnchorHEC on a physical robot. Project page: this https URL
8 pages, 5 figures, 5 tables. Project page: this https URL
Robotics (cs.RO)
arXiv:2611.02884 [cs.RO]
(or arXiv:2611.02884v1 [cs.RO] for this version)
https://doi.org/10.48550/arXiv.2611.02884 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 268 words