Off-topic for aiqbench
This story was gathered from a source we follow but falls outside AI and quantum coverage, so there is no aiqbench take for it.
An MRI-Guided Robotic System to Improve Hippocampal Access for Epilepsy Interventions
arXiv:2609.13572v1 Announce Type: new Abstract: This paper presents an MRI-guided robotic system that improves hippocampal access by delivering a curved needle-like laser ablator through the foramen ovale, a natural opening in the base of the skull. Both the delivery path and the curved nature of the needle improve upon current clinical straight-line laser interstitial thermal therapy (LITT) as measured by hippocampal cannulation percentage. We describe the design of the robotic system which includes positioning, aiming, and curved needle deployment stages, followed by experimental results assessing cannulation percentages using MRI images in phantoms. In three curvilinear, single-insertion experiments, we achieved cannulation percentages of 93.5%, 96.5%, and 60.4%, exceeding reported clinical averages of 50-60%. Seizure control is believed by physicians to be a function of hippocampal volume treated, and our system provides a means of treating a greater volume of the hippocampus with LITT-based interventions.
Authors:John E. Peters, Abby M. Grillo, Mahshid Mansouri, Daniel S. Esser, Sarah Garrow, Nithin S. Kumar, Dario J. Englot, Joseph S. Neimat, William A. Grissom, Robert J. Webster III, Eric J. Barth
Abstract:This paper presents an MRI-guided robotic system that improves hippocampal access by delivering a curved needle-like laser ablator through the foramen ovale, a natural opening in the base of the skull. Both the delivery path and the curved nature of the needle improve upon current clinical straight-line laser interstitial thermal therapy (LITT) as measured by hippocampal cannulation percentage. We describe the design of the robotic system which includes positioning, aiming, and curved needle deployment stages, followed by experimental results assessing cannulation percentages using MRI images in phantoms. In three curvilinear, single-insertion experiments, we achieved cannulation percentages of 93.5%, 96.5%, and 60.4%, exceeding reported clinical averages of 50-60%. Seizure control is believed by physicians to be a function of hippocampal volume treated, and our system provides a means of treating a greater volume of the hippocampus with LITT-based interventions.
Robotics (cs.RO)
arXiv:2609.13572 [cs.RO]
(or arXiv:2609.13572v1 [cs.RO] for this version)
https://doi.org/10.48550/arXiv.2609.13572 arXiv-issued DOI via DataCite (pending registration)
Full text under the publisher's open licence · 187 words
Related coverage
Problems of Proliferation
LessWrong · Sep 29, 2026
The J-Space Debate, Agent Swarms, and Pacing Frontier AI - Digital Minds Newsletter #4
LessWrong · Sep 18, 2026
Links #5: 2026/07
LessWrong · Jul 31, 2026

BRICS Draws a New Global Line: Full Text of New Delhi Declaration
slguardian.org · Sep 12, 2026