aiqbench analysis
This multi-site study demonstrates that while Large Language Models can effectively abstract structured clinical data, their accuracy degrades significantly when faced with ambiguous questions requiring complex clinical reasoning. The research provides a critical taxonomy of ambiguity levels, revealing that performance drops from 96% on simple flags to just 62% on timing events where human consensus is high. For the AI community, this highlights the current limitations of unprocessed EMR data ingestion and underscores the need for specialized fine-tuning or hybrid workflows in high-stakes medical applications.
An ambiguity taxonomy for evaluating large language model performance on clinical registry abstraction: a multi-site prospective study
arXiv:2608.20373v1 Announce Type: new Abstract: Objective: To evaluate large language model (LLM) performance on unprocessed electronic medical record (EMR) data for clinical registry abstraction. Methods: We evaluated LLM performance answering registry questions for the American College of Cardiology National Cardiovascular Data Registry (ACC NCDR). In a pilot study at an academic medical center, the model identified candidate data sources for each registry question and experienced abstractors used these results to define question-specific document sets. In a validation study at a second center with a second ACC NCDR registry, the LLM answered questions using the question-specific document sets. Before reviewing any output, two abstractors independently established the ground truth and assigned each question to one of six categories, ordered by the ambiguity and clinical reasoning required to resolve it: Medication/Event Flag, Binary Clinical Presence, Administrative, Quantitative Laboratory/Physiologic, Clinical Interpretation, and Event Timing. Results: The analytical sample comprised 9,430 abstractor answers reconciled to 4,715 consensus answers (501 pilot; 4,214 validation). In the pilot, candidate data sources per question averaged between 14.6 (SD 13.9) for demographics and 89.2 (SD 56.1) for history and risk factors. In validation, human inter-rater agreement was approximately 98\% while 87\% of LLM answers exactly matched consensus, 2\% partially, and 9\% did not. Mean question-level accuracy was 91.5\% (SD 13.4\%) across 157 questions with at least 20 answers, and declined as ambiguity increased, from 96\% for Medication/Event Flag to 62\% for Event Timing questions. Conclusions: LLMs answering clinical registry questions on unprocessed EMR data achieved far lower accuracy than human abstractors. LLM accuracy fell steadily as ambiguity and the level of required clinical reasoning increased.
Abstract:Objective: To evaluate large language model (LLM) performance on unprocessed electronic medical record (EMR) data for clinical registry abstraction. Methods: We evaluated LLM performance answering registry questions for the American College of Cardiology National Cardiovascular Data Registry (ACC NCDR). In a pilot study at an academic medical center, the model identified candidate data sources for each registry question and experienced abstractors used these results to define question-specific document sets. In a validation study at a second center with a second ACC NCDR registry, the LLM answered questions using the question-specific document sets. Before reviewing any output, two abstractors independently established the ground truth and assigned each question to one of six categories, ordered by the ambiguity and clinical reasoning required to resolve it: Medication/Event Flag, Binary Clinical Presence, Administrative, Quantitative Laboratory/Physiologic, Clinical Interpretation, and Event Timing. Results: The analytical sample comprised 9,430 abstractor answers reconciled to 4,715 consensus answers (501 pilot; 4,214 validation). In the pilot, candidate data sources per question averaged between 14.6 (SD 13.9) for demographics and 89.2 (SD 56.1) for history and risk factors. In validation, human inter-rater agreement was approximately 98\% while 87\% of LLM answers exactly matched consensus, 2\% partially, and 9\% did not. Mean question-level accuracy was 91.5\% (SD 13.4\%) across 157 questions with at least 20 answers, and declined as ambiguity increased, from 96\% for Medication/Event Flag to 62\% for Event Timing questions. Conclusions: LLMs answering clinical registry questions on unprocessed EMR data achieved far lower accuracy than human abstractors. LLM accuracy fell steadily as ambiguity and the level of required clinical reasoning increased.
Computation and Language (cs.CL)
arXiv:2608.20373 [cs.CL]
(or arXiv:2608.20373v1 [cs.CL] for this version)
https://doi.org/10.48550/arXiv.2608.20373 Focus to learn more arXiv-issued DOI via DataCite
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 354 words
Related coverage
Amazon is investing in the Lean Focused Research Organization
Amazon Science · Jul 26, 2026

34 Amazon Research Awards Build on Trainium recipients announced
Amazon Science · Aug 5, 2026

Amazon Research Awards recipients announced
Amazon Science · May 27, 2026
The Continual Constitutional Convention: How language models revise the documents that govern them
AI Alignment Forum · Oct 13, 2026