Skip to content
aiqbench takeMachine Learning

aiqbench analysis

This paper presents a rigorous mathematical framework for calibrating stochastic digital twins in bioprocesses, leveraging adjoint sensitivity analysis and actor-simulator algorithms to optimize control policies under uncertainty. By explicitly addressing parameter bias and propagation of errors, the work advances the intersection of machine learning theory and complex physical system modeling. It offers significant methodological value for researchers developing high-fidelity AI-driven simulations in scientific domains.
Source coveringarXiv
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Adjoint-Based Calibration and Optimal Control of Stochastic Multiscale Bioprocess Digital Twins

arXiv2 min read

arXiv:2610.09505v1 Announce Type: cross Abstract: We develop a bias-aware digital-twin calibration and control framework for multiscale bioprocess models within a biological systems-of-systems (Bio-SoS) paradigm. The digital twin is represented by a stochastic differential equation (SDE) model and calibrated from sparse, discrete observations using quasi-likelihood estimation and adjoint sensitivity analysis. SDE generator-based moment expansions characterize truncation-induced parameter bias, while forward-backward adjoints quantify how calibration uncertainty propagates to value functions and policy performance. The resulting parameter-error distribution supports both policy-directed adaptive experimental design and uncertainty-aware policy optimization through a second-order Gaussian-averaged objective. We characterize the asymptotic behavior of the resulting exploration criterion and derive a physical-system performance under the optimized policy. To implement these ideas, we develop an Actor-Simulator algorithm that jointly updates model parameters, selects informative experiments, and optimizes control policies. Numerical studies demonstrate improved calibration accuracy, sample efficiency, and control performance relative to state-of-the-art baselines.

Abstract:We develop a bias-aware digital-twin calibration and control framework for multiscale bioprocess models within a biological systems-of-systems (Bio-SoS) paradigm. The digital twin is represented by a stochastic differential equation (SDE) model and calibrated from sparse, discrete observations using quasi-likelihood estimation and adjoint sensitivity analysis. SDE generator-based moment expansions characterize truncation-induced parameter bias, while forward-backward adjoints quantify how calibration uncertainty propagates to value functions and policy performance. The resulting parameter-error distribution supports both policy-directed adaptive experimental design and uncertainty-aware policy optimization through a second-order Gaussian-averaged objective. We characterize the asymptotic behavior of the resulting exploration criterion and derive a physical-system performance under the optimized policy. To implement these ideas, we develop an Actor-Simulator algorithm that jointly updates model parameters, selects informative experiments, and optimizes control policies. Numerical studies demonstrate improved calibration accuracy, sample efficiency, and control performance relative to state-of-the-art baselines.

Machine Learning (stat.ML); Machine Learning (cs.LG)

arXiv:2610.09505 [stat.ML]

(or arXiv:2610.09505v1 [stat.ML] for this version)

https://doi.org/10.48550/arXiv.2610.09505 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 237 words

Related coverage