Skip to content
aiqbench takeQuantum Computing

aiqbench analysis

This study establishes an absolute frequency measurement for the $^{40}$Ca$^{+}$ optical clock transition by linking a laboratory setup to the SI second via GNSS, achieving a fractional uncertainty of 1.5 $\times$ 10$^{-15}$. The work refines fundamental constants, specifically reevaluating the Landé g-factor for the $3d$ $^{2}D_{5/2}$ level, which is critical for next-generation atomic clocks and precision metrology.
Sources coveringarXiv, AI Alignment Forum, Quantum Zeitgeist
What this isA model's reading of the article and related coverage, written for aiqbench. Not the publisher's words.

Absolute frequency measurement of the $^{40}$Ca$^{+}$ clock transition using a GNSS link to the SI second

arXiv2 min read

arXiv:2609.15844v1 Announce Type: cross Abstract: We report the absolute frequency measurement of the $4s$ $ ^{2}S_{1/2}\leftrightarrow 3d$ $^{2}D_{5/2}$ $^{40}$Ca$^{+}$ clock transition with respect to the SI second. To perform this measurement, a link between our laboratory in Innsbruck and the clocks realizing the Coordinated Universal Time at the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig was installed and characterized using the Global Navigation Satellite System GNSS. The comparison between our clock and the ones at PTB was done using the Precise Point Positioning technique. After the evaluation of the systematic shifts, the measured transition frequency is 411 042 129 776 401.2$\pm$0.6 Hz with a fractional uncertainty of 1.5 $\times$ 10$^{-15}$. The stability of the clock measurements was also corroborated by comparing two different calcium ion clock experiments, which share the clock laser source at our institute. Furthermore, after careful evaluation of the trap-drive induced ac magnetic fields, we estimate ac Zeeman shifts on the $D_{5/2}$ sublevels and reevaluate the Land\'e g-factor of the $3d$ $^{2}D_{5/2}$ level to be g$_{5/2}= 1.200329(1)$.

Abstract:We report the absolute frequency measurement of the $4s$ $ ^{2}S_{1/2}\leftrightarrow 3d$ $^{2}D_{5/2}$ $^{40}$Ca$^{+}$ clock transition with respect to the SI second. To perform this measurement, a link between our laboratory in Innsbruck and the clocks realizing the Coordinated Universal Time at the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig was installed and characterized using the Global Navigation Satellite System GNSS. The comparison between our clock and the ones at PTB was done using the Precise Point Positioning technique. After the evaluation of the systematic shifts, the measured transition frequency is 411 042 129 776 401.2$\pm$0.6 Hz with a fractional uncertainty of 1.5 $\times$ 10$^{-15}$. The stability of the clock measurements was also corroborated by comparing two different calcium ion clock experiments, which share the clock laser source at our institute. Furthermore, after careful evaluation of the trap-drive induced ac magnetic fields, we estimate ac Zeeman shifts on the $D_{5/2}$ sublevels and reevaluate the Landé g-factor of the $3d$ $^{2}D_{5/2}$ level to be g$_{5/2}= 1.200329(1)$.

Atomic Physics (physics.atom-ph); Quantum Physics (quant-ph)

arXiv:2609.15844 [physics.atom-ph]

(or arXiv:2609.15844v1 [physics.atom-ph] for this version)

https://doi.org/10.48550/arXiv.2609.15844 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Full text under the publisher's open licence · 260 words