aiqbench analysis
This study advances the precision of optical atomic clocks by reducing frequency uncertainty to $2.6\times10^{-16}$, a critical milestone for next-generation quantum sensing and timekeeping infrastructure. The improved measurement reinforces the international standard for time while demonstrating robust remote synchronization capabilities essential for global quantum networks.
Absolute frequency measurement of a $^{176}$Lu$^+\,(^{3}\mathrm{D}_1)$ standard against the NRC-FCs2 fountain with $2.6\times10^{-16}$ uncertainty
arXiv:2607.07044v2 Announce Type: replace-cross Abstract: We report an improved absolute frequency measurement of the $^{176}$Lu$^+\,(^{3}\mathrm{D}_1)$ optical frequency standard, evaluated via a remote link to the NRC-FCs2 caesium fountain primary frequency standard. Operating a single ion clock with 94.2% uptime over 10 days, and using an ambiguity-resolved precise point positioning (PPP-AR) link over the Global Positioning System, we determine an absolute frequency of $353\,638\,794\,073\,800.332(91)\,$Hz at a fractional uncertainty of $2.6 \times 10^{-16}$. This agrees with our previous result, which underpins the Comit\'e international des poids et mesures recommended frequency value, and reduces the uncertainty by a factor of 3.6.
Title:Absolute frequency measurement of a $^{176}$Lu$^+\,(^{3}\mathrm{D}_1)$ standard against the NRC-FCs2 fountain with $2.6\times10^{-16}$ uncertainty
Abstract:We report an improved absolute frequency measurement of the $^{176}$Lu$^+\,(^{3}\mathrm{D}_1)$ optical frequency standard, evaluated via a remote link to the NRC-FCs2 caesium fountain primary frequency standard. Operating a single ion clock with 94.2% uptime over 10 days, and using an ambiguity-resolved precise point positioning (PPP-AR) link over the Global Positioning System, we determine an absolute frequency of $353\,638\,794\,073\,800.332(91)\,$Hz at a fractional uncertainty of $2.6 \times 10^{-16}$. This agrees with our previous result, which underpins the Comité international des poids et mesures recommended frequency value, and reduces the uncertainty by a factor of 3.6.
Atomic Physics (physics.atom-ph); Quantum Physics (quant-ph)
arXiv:2607.07044 [physics.atom-ph]
(or arXiv:2607.07044v2 [physics.atom-ph] for this version)
https://doi.org/10.48550/arXiv.2607.07044 Focus to learn more arXiv-issued DOI via DataCite
https://doi.org/10.1088/1681-7575/aea166 Focus to learn more DOI(s) linking to related resources
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Full text under the publisher's open licence · 212 words
Related coverage

Researchers Measure Calcium Clock Frequency with 0.6Hz Uncertainty
Quantum Zeitgeist · Sep 18, 2026
A nuclear clock synchronized to $^{229}$Th
arXiv · Oct 8, 2026
Qubit Noise Sensing via Induced Photon Loss in a Superconducting Cavity
arXiv · Oct 6, 2026
Torsion balances as operational probes of semiclassical gravity: Matched-filter bounds, torque-diffusion constraints, and quantum-noise benchmarks
arXiv · Aug 27, 2026