analiza aiqbench
This study establishes a hard physical limit on ultra-low-field MRI super-resolution, proving that generative models trained on synthetic data often fabricate details exceeding the actual information captured by real scanners. By demonstrating that fine output features correlate equally well with the original subject or strangers, the research exposes the fundamental unreliability of standard metrics like PSNR and SSIM for validating medical imaging fidelity. This work is critical for AI safety in healthcare, urging a shift toward benchmarks that respect the true information ceiling of low-field hardware rather than rewarding hallucinated precision.
You Cannot Recover What Was Never Measured: Quantifying the Information Ceiling of Ultra-Low-Field MRI Super-Resolution
arXiv:2609.36837v1 Announce Type: cross Abstract: Generative super-resolution models can turn portable 64 mT MRI into images that look like 3T scans, and the field evaluates them with PSNR, SSIM, and pixelwise uncertainty, most often on pairs built by synthetically degrading high-field images. Prior work acknowledges that these models hallucinate and that the problem is ill posed, but to our knowledge no study measures how much information about the individual subject the real low-field scan actually contains. We measure it. Using paired 64 mT and 3T scans of the same subjects from three public datasets, and a measurement protocol validated on tests whose correct answer is known in advance, we find that, judged over the whole brain, real 64 mT scans carry structure specific to the individual only down to approximately 3 to 4 mm half-pitch in plane, and coarser still through plane. Standard synthetic degradations preserve subject information roughly 1 mm beyond this ceiling, so models trained and benchmarked on synthetic pairs are evaluated on information that real scanners never record. We then test trained diffusion models and a publicly released external model on real paired acquisitions; 24 trained runs of five architectures (GAN, diffusion, and transformer families) give the coverage of the audit. On every subject where faithfulness can be measured, fine output detail is no more correlated with the subject's own 3T scan than with a stranger's, while sample-variance uncertainty does not distinguish fabricated structure from reconstruction difficulty. Because PSNR and SSIM score resemblance to a reference rather than whether detail belongs to the subject, a benchmark scored by them cannot tell recovery from fabrication. Code for the measurement protocol will be released so that recoverability claims can be tested for newer models.
Abstract:Generative super-resolution models can turn portable 64 mT MRI into images that look like 3T scans, and the field evaluates them with PSNR, SSIM, and pixelwise uncertainty, most often on pairs built by synthetically degrading high-field images. Prior work acknowledges that these models hallucinate and that the problem is ill posed, but to our knowledge no study measures how much information about the individual subject the real low-field scan actually contains. We measure it. Using paired 64 mT and 3T scans of the same subjects from three public datasets, and a measurement protocol validated on tests whose correct answer is known in advance, we find that, judged over the whole brain, real 64 mT scans carry structure specific to the individual only down to approximately 3 to 4 mm half-pitch in plane, and coarser still through plane. Standard synthetic degradations preserve subject information roughly 1 mm beyond this ceiling, so models trained and benchmarked on synthetic pairs are evaluated on information that real scanners never record. We then test trained diffusion models and a publicly released external model on real paired acquisitions; 24 trained runs of five architectures (GAN, diffusion, and transformer families) give the coverage of the audit. On every subject where faithfulness can be measured, fine output detail is no more correlated with the subject's own 3T scan than with a stranger's, while sample-variance uncertainty does not distinguish fabricated structure from reconstruction difficulty. Because PSNR and SSIM score resemblance to a reference rather than whether detail belongs to the subject, a benchmark scored by them cannot tell recovery from fabrication. Code for the measurement protocol will be released so that recoverability claims can be tested for newer models.
Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG); Medical Physics (physics.med-ph)
arXiv:2609.36837 [cs.CV]
(or arXiv:2609.36837v1 [cs.CV] for this version)
https://doi.org/10.48550/arXiv.2609.36837 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 383 cuvinte
Subiecte conexe

Deconfusing Corrigibility
AI Alignment Forum · 17 oct. 2026
DI Series: Serving Kimi-K3 MXFP4 Wide-EP Disaggregated on AMD Instinct MI300X and MI325X
AMD · 8 oct. 2026

Lattice-Based Cryptography Explained
Quantum Zeitgeist · 15 aug. 2026

[AINews] not much happened today
Latent Space · 3 oct. 2026