Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchMachine learning

analiza aiqbench

This study investigates transfer learning in ultrasound imaging by testing whether encoders pretrained on high-resource echocardiography data improve tuberculosis screening models for low-resource lung ultrasound datasets. The results indicate that feature conditioning between the encoder and classifier is the primary driver of performance gains, rather than the specific domain knowledge transferred from cardiac to lung scans. Ultimately, the research highlights that limited labeled cohorts in medical imaging constrain model performance more significantly than the choice of pretraining corpus or architectural family.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Wrong Organ, Right Physics: Transferring Echocardiography Pretraining to Lung Ultrasound for Tuberculosis Screening

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2610.03290v1 Announce Type: cross Abstract: Lung ultrasound (LUS) is attractive for tuberculosis (TB) screening at primary-care level, but labelled cohorts are small. Echocardiography carries no such constraint, while sharing the same underlying ultrasound imaging physics, signal processing and B-mode appearance as LUS. We ask whether an encoder pretrained on that high-resource ultrasound domain carries representations that remain usable in the low-resource one. Only the encoder varies, across seventeen encoders spanning three architecture families. Among them, a latent-predictive video encoder pretrained on generic video (V-JEPA2-L) and its echocardiography counterpart (EchoJEPA-L) differ in pretraining corpus alone. The choice among these encoders does not resolve the classification, the whole family spanning 2.50 percentage points against a measurement resolution of 2.71. What moves the task instead is feature conditioning. Standardising the features between the encoder and the classifier improves all seventeen encoders by a mean of +1.23 percentage points at $p=1.5\times10^{-5}$. On the held-out test set every encoder selected on the development folds stands above the baseline system by up to +2.57 percentage points of area under the receiver operating characteristic curve (AUROC), and specificity at 90% sensitivity reaches 79.3% against 60.3%. The contrast specified in advance, EchoJEPA-L against V-JEPA2-L, measures -0.16 percentage points at $p=0.926$. We therefore find no evidence that shared ultrasonic physics alone makes echocardiography a more productive pretraining corpus than generic video, and any advantage, if present, is smaller than this cohort can resolve. The video encoders receive replicated still images, however, so whether this absence of an effect reflects the pretraining domain or a video encoder applied to static frames cannot be separated. The limiting factor is the labelled cohort rather than the encoder.

Abstract:Lung ultrasound (LUS) is attractive for tuberculosis (TB) screening at primary-care level, but labelled cohorts are small. Echocardiography carries no such constraint, while sharing the same underlying ultrasound imaging physics, signal processing and B-mode appearance as LUS. We ask whether an encoder pretrained on that high-resource ultrasound domain carries representations that remain usable in the low-resource one. Only the encoder varies, across seventeen encoders spanning three architecture families. Among them, a latent-predictive video encoder pretrained on generic video (V-JEPA2-L) and its echocardiography counterpart (EchoJEPA-L) differ in pretraining corpus alone. The choice among these encoders does not resolve the classification, the whole family spanning 2.50 percentage points against a measurement resolution of 2.71. What moves the task instead is feature conditioning. Standardising the features between the encoder and the classifier improves all seventeen encoders by a mean of +1.23 percentage points at $p=1.5\times10^{-5}$. On the held-out test set every encoder selected on the development folds stands above the baseline system by up to +2.57 percentage points of area under the receiver operating characteristic curve (AUROC), and specificity at 90% sensitivity reaches 79.3% against 60.3%. The contrast specified in advance, EchoJEPA-L against V-JEPA2-L, measures -0.16 percentage points at $p=0.926$. We therefore find no evidence that shared ultrasonic physics alone makes echocardiography a more productive pretraining corpus than generic video, and any advantage, if present, is smaller than this cohort can resolve. The video encoders receive replicated still images, however, so whether this absence of an effect reflects the pretraining domain or a video encoder applied to static frames cannot be separated. The limiting factor is the labelled cohort rather than the encoder.

10 pages, 3 figures, 4 tables. Accepted at SATNAC 2026, Drakensberg, South Africa, 11-14 October 2026

Image and Video Processing (eess.IV); Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG)

I.4.9; I.5.4; J.3; I.2.6

arXiv:2610.03290 [eess.IV]

(or arXiv:2610.03290v1 [eess.IV] for this version)

https://doi.org/10.48550/arXiv.2610.03290 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 395 cuvinte

Subiecte conexe