Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchMachine learning

analiza aiqbench

This study exposes a critical flaw in evaluating clinical trajectory simulators, demonstrating that high next-event accuracy fails to predict compounded errors during closed-loop generation. The authors introduce EDSim-Bench, which reveals that standard neural architectures often diverge significantly from baseline n-gram models when generating full patient visits, particularly regarding event composition and timing. These findings necessitate a shift toward rigorous rollout-based evaluation protocols before deploying such models in high-stakes healthcare environments.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

What Next-Event Accuracy Cannot See: Closed-Loop Evaluation of Emergency Department Trajectory Simulators

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2609.31635v1 Announce Type: new Abstract: Clinical trajectory models are usually evaluated by next-event accuracy on observed histories. Simulation is different: models must condition on their own generated events, allowing errors to compound. Although this problem is well known in sequence modelling, it has not been systematically quantified for clinical trajectory simulators. We developed EDSim-Bench to evaluate this failure mode using 425,028 MIMIC-IV-ED stays, with external replication on MC-MED, and release the evaluation protocol and scoring code. Starting from held-out visit prefixes, models generate the remainder of each visit and are evaluated on termination, event composition, timing, conditional fidelity, and occupancy forecasting, with a train-only order-3 n-gram as a reference baseline. Despite next-event accuracies within 0.001, three neural architectures behaved very differently under rollout. Across seeds, one Transformer recipe ranged from 0.43 to 0.96 in termination score and from 4.2- to 137-fold the divergence of the n-gram; no prefix-trained neural model approached the n-gram on termination or event composition. Inference-time interventions improved termination but did not jointly recover composition and timing. Supervising every eligible sequence position rather than only the final prefix position was associated with one to two orders of magnitude lower divergence across Transformer, GRU, and LSTM models, with the pattern persisting under model scaling, temporal shift, and external-site evaluation. Nevertheless, even the best model generated visits approximately half as long as observed, and model rankings reversed on occupancy forecasting, a downstream quantity relevant to bed management. These results show that next-event accuracy is insufficient to evaluate clinical trajectory simulators and motivate closed-loop evaluation across seeds, rollout criteria, and downstream tasks.

Abstract:Clinical trajectory models are usually evaluated by next-event accuracy on observed histories. Simulation is different: models must condition on their own generated events, allowing errors to compound. Although this problem is well known in sequence modelling, it has not been systematically quantified for clinical trajectory simulators. We developed EDSim-Bench to evaluate this failure mode using 425,028 MIMIC-IV-ED stays, with external replication on MC-MED, and release the evaluation protocol and scoring code. Starting from held-out visit prefixes, models generate the remainder of each visit and are evaluated on termination, event composition, timing, conditional fidelity, and occupancy forecasting, with a train-only order-3 n-gram as a reference baseline. Despite next-event accuracies within 0.001, three neural architectures behaved very differently under rollout. Across seeds, one Transformer recipe ranged from 0.43 to 0.96 in termination score and from 4.2- to 137-fold the divergence of the n-gram; no prefix-trained neural model approached the n-gram on termination or event composition. Inference-time interventions improved termination but did not jointly recover composition and timing. Supervising every eligible sequence position rather than only the final prefix position was associated with one to two orders of magnitude lower divergence across Transformer, GRU, and LSTM models, with the pattern persisting under model scaling, temporal shift, and external-site evaluation. Nevertheless, even the best model generated visits approximately half as long as observed, and model rankings reversed on occupancy forecasting, a downstream quantity relevant to bed management. These results show that next-event accuracy is insufficient to evaluate clinical trajectory simulators and motivate closed-loop evaluation across seeds, rollout criteria, and downstream tasks.

Machine Learning (cs.LG); Artificial Intelligence (cs.AI)

arXiv:2609.31635 [cs.LG]

(or arXiv:2609.31635v1 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2609.31635 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 352 cuvinte

Subiecte conexe