Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchSiguranță AI

analiza aiqbench

This research demonstrates how reinforcement learning can train vision-language models to generate medical checklists that inadvertently introduce bias when validating unmentioned findings in radiology reports. The study highlights a critical safety concern where model performance metrics diverge significantly between training formats and independent evaluations, underscoring the risks of relying on AI-generated labels rather than radiologist-adjudicated data for automated checking systems.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Unmentioned Checklist Findings Change How Reinforcement Learning Appears to Improve Chest Radiograph Report Checking

arXiv2 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2610.05425v1 Announce Type: cross Abstract: Automated checks of radiology reports may rely on AI-generated checklists that leave findings unmentioned. We used reinforcement learning to train a vision-language model to fill in a 12-finding checklist from a chest radiograph without seeing the sentence under test; a separate checking model judged the sentence from the checklist. On held-out patients, a rule-based check and an independent medical checker, neither used in training, measured discrimination gains (Youden index) of 12.6% and 11.8%; only the rule-based check met the prespecified false-alarm criterion. Switching to the training format, which fixes finding order and enters unmentioned findings as absent, raised the training checker's measured gain and lowered the independent checker's, a prespecified comparison that yielded 6.2% (95% interval 2.0% to 10.5%) and, post hoc on held-out patients, 7.7%. Across 8 checking models, acceptance of a label-consistent negative statement about an unmentioned finding ranged from 1.0% to 97.0%. Labels were report-derived, not radiologist-adjudicated.

Abstract:Automated checks of radiology reports may rely on AI-generated checklists that leave findings unmentioned. We used reinforcement learning to train a vision-language model to fill in a 12-finding checklist from a chest radiograph without seeing the sentence under test; a separate checking model judged the sentence from the checklist. On held-out patients, a rule-based check and an independent medical checker, neither used in training, measured discrimination gains (Youden index) of 12.6% and 11.8%; only the rule-based check met the prespecified false-alarm criterion. Switching to the training format, which fixes finding order and enters unmentioned findings as absent, raised the training checker's measured gain and lowered the independent checker's, a prespecified comparison that yielded 6.2% (95% interval 2.0% to 10.5%) and, post hoc on held-out patients, 7.7%. Across 8 checking models, acceptance of a label-consistent negative statement about an unmentioned finding ranged from 1.0% to 97.0%. Labels were report-derived, not radiologist-adjudicated.

40 pages, 7 figures, 17 tables (main text and references pp. 1-19; Supplementary Information as an appendix, pp. 20-40). Submitted to npj Digital Medicine. Code: this https URL

Computer Vision and Pattern Recognition (cs.CV); Computation and Language (cs.CL); Machine Learning (cs.LG)

arXiv:2610.05425 [cs.CV]

(or arXiv:2610.05425v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2610.05425 arXiv-issued DOI via DataCite (pending registration)

Text integral sub licența deschisă a publicației · 206 cuvinte

Subiecte conexe