This research proposes an end-to-end deep learning framework that bypasses traditional, manual mesh generation steps by directly converting medical imaging data into high-fidelity cardiac surface meshes using Transformers and Graph Attention Networks. By prioritizing geometric fidelity over standard segmentation metrics like Dice scores, the study addresses a critical bottleneck in creating patient-specific digital twins for clinical simulation. The approach significantly reduces reliance on specialist knowledge while maintaining topological correctness essential for accurate hemodynamic modeling.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Transformer-Guided Graph Attention for Direct Cardiac Mesh Reconstruction: A Structural Digital Twin Framework

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2606.13188v1 Announce Type: cross Abstract: Building patient-specific cardiac models sits at the heart of precision cardiology, yet getting those models into clinical use keeps running into the same wall: mesh generation is slow, messy, and frustrating. The standard workflow -- segmenting the image, running Marching Cubes, and then manually cleaning up the result -- is time-consuming, inconsistent across operators, and demands specialist knowledge most clinical teams do not have. We take a fundamentally different approach. Instead of treating segmentation and mesh generation as two separate problems, we train a single end-to-end network that goes directly from a raw 3D medical image to a smooth, simulation-ready cardiac surface mesh. The core is a 3D Swin Transformer encoder-decoder that extracts volumetric features from CT or MRI volumes, paired with a Graph Attention Network (GAT) head that iteratively deforms a template mesh to fit the patient's cardiac boundary. We tested on the MM-WHS 2017 benchmark using both CT and MRI. Segmentation scores were competitive (Dice of 0.84 on CT, 0.83 on MRI), but the primary focus is mesh quality: mean Chamfer distance of 1.8 mm, with 95th-percentile surface distance below 5 mm. Every mesh is produced in a single forward pass -- no Marching Cubes, no smoothing filters, no manual cleanup. We argue that for cardiac digital twin pipelines, geometric fidelity and topological correctness matter more than pixel-level Dice scores. By removing the post-processing bottleneck, this approach makes patient-specific cardiac simulation substantially more accessible for clinical use.

Abstract:Building patient-specific cardiac models sits at the heart of precision cardiology, yet getting those models into clinical use keeps running into the same wall: mesh generation is slow, messy, and frustrating. The standard workflow -- segmenting the image, running Marching Cubes, and then manually cleaning up the result -- is time-consuming, inconsistent across operators, and demands specialist knowledge most clinical teams do not have. We take a fundamentally different approach. Instead of treating segmentation and mesh generation as two separate problems, we train a single end-to-end network that goes directly from a raw 3D medical image to a smooth, simulation-ready cardiac surface mesh. The core is a 3D Swin Transformer encoder-decoder that extracts volumetric features from CT or MRI volumes, paired with a Graph Attention Network (GAT) head that iteratively deforms a template mesh to fit the patient's cardiac boundary. We tested on the MM-WHS 2017 benchmark using both CT and MRI. Segmentation scores were competitive (Dice of 0.84 on CT, 0.83 on MRI), but the primary focus is mesh quality: mean Chamfer distance of 1.8 mm, with 95th-percentile surface distance below 5 mm. Every mesh is produced in a single forward pass -- no Marching Cubes, no smoothing filters, no manual cleanup. We argue that for cardiac digital twin pipelines, geometric fidelity and topological correctness matter more than pixel-level Dice scores. By removing the post-processing bottleneck, this approach makes patient-specific cardiac simulation substantially more accessible for clinical use.

Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)

arXiv:2606.13188 [cs.CV]

(or arXiv:2606.13188v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2606.13188 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 339 cuvinte

Subiecte conexe