This research proposes a mechanical modeling approach to decouple normal and shear interface pressures in prosthetic sockets, addressing the limitations of traditional sensors that suffer from drift and sparse data coverage. By leveraging global wrench measurements alongside sparse local sensing, the study uses convex least-squares optimization to improve fit metrics without requiring full-field pressure estimates. The work offers a promising pathway for augmenting existing hardware with algorithmic models to enable more objective, long-term biomechanical analysis in robotic prosthetics.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Towards Estimating Normal and Shear Interface Pressures in Prosthetic Sockets via Least Squares and Mechanics Modeling

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2606.04222v1 Announce Type: new Abstract: Prosthetic socket fitting remains largely manual and iterative, and objective fit metrics are still limited. Part of the challenge is the lack of long-term real-life pressure data at the residual limb--socket interface. Traditional pressure sensors are prone to drift over time, and capture only normal pressures at sparse locations within the socket, missing a critical component for biomechanical analysis: shear. Although some sensors can report both normal and shear interface stresses, these components are often difficult to decouple because of measurement crosstalk. One potential path forward is to develop models that can augment available measurements. This work introduces a testbed to evaluate model performance under sparse pressure sensing using two complementary validation signals: (i) the global wrench (\ie, total forces and moments expressed in an orthonormal frame) transmitted through the socket, by an artificial residual-limb, and (ii) local interface loads (\ie, decoupled normal and shear pressure components in a right-hand-rule orthogonal frame that lives in each instrumented location) measured by sparse sensing clusters, each composed of four capacitance-sensing channels. Rather than presenting full-field pressure estimates, the focus is on an analysis sequence that quantifies how well candidate mechanical models explain both global and local measurements under controlled conditions. A quasi-static spring--mass contact model is evaluated, and its parameters are identified via a two-stage convex least-squares problem. Validation under static loading shows that estimating constant bias terms reduces steady offsets in the wrench channels and improves agreement with local measurements. A Pareto-front sensitivity analysis further illustrates how the trade-off between global and local objectives changes when bias terms are included.

Abstract:Prosthetic socket fitting remains largely manual and iterative, and objective fit metrics are still limited. Part of the challenge is the lack of long-term real-life pressure data at the residual limb--socket interface. Traditional pressure sensors are prone to drift over time, and capture only normal pressures at sparse locations within the socket, missing a critical component for biomechanical analysis: shear. Although some sensors can report both normal and shear interface stresses, these components are often difficult to decouple because of measurement crosstalk. One potential path forward is to develop models that can augment available measurements. This work introduces a testbed to evaluate model performance under sparse pressure sensing using two complementary validation signals: (i) the global wrench (\ie, total forces and moments expressed in an orthonormal frame) transmitted through the socket, by an artificial residual-limb, and (ii) local interface loads (\ie, decoupled normal and shear pressure components in a right-hand-rule orthogonal frame that lives in each instrumented location) measured by sparse sensing clusters, each composed of four capacitance-sensing channels. Rather than presenting full-field pressure estimates, the focus is on an analysis sequence that quantifies how well candidate mechanical models explain both global and local measurements under controlled conditions. A quasi-static spring--mass contact model is evaluated, and its parameters are identified via a two-stage convex least-squares problem. Validation under static loading shows that estimating constant bias terms reduces steady offsets in the wrench channels and improves agreement with local measurements. A Pareto-front sensitivity analysis further illustrates how the trade-off between global and local objectives changes when bias terms are included.

Robotics (cs.RO)

arXiv:2606.04222 [cs.RO]

(or arXiv:2606.04222v1 [cs.RO] for this version)

https://doi.org/10.48550/arXiv.2606.04222 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 350 cuvinte

Subiecte conexe