Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchComunicații cuantice

analiza aiqbench

This research introduces a time-rescaled STIRAP protocol that significantly reduces the physical length required for robust, full frequency conversion in optical devices. By approximating complex coupling coefficients with Gaussian functions, the method simplifies experimental implementation while maintaining high fidelity for applications like single-photon detection in the mid-infrared. The work represents a notable advancement in quantum optics and photonic circuit design, directly addressing the need for more compact quantum hardware components.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Time-Rescaled STIRAP Enables Compact Cascaded Frequency Conversion

arXiv2 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2602.18930v2 Announce Type: replace Abstract: In this letter we explore how full frequency conversion can be performed in shorter optical devices by using a STIRAP-like protocol modified by the time rescaling shortcut to adiabaticity. We first show a detailed, step-by-step process of how the coupled equations for two simultaneous three-wave mixing processes can be written in terms of a STIRAP-like system. From the properties of the STIRAP protocol, we know that the ensuing process will result in robust conversion, but require long propagation distances inside the bulk crystal or waveguide. We then apply the time rescaling shortcut to adiabaticty in the conversion process to create a TR-STIRAP protocol, showing that full and robust conversion is also obtained, but at a fraction of the propagation distance. We also show how the original shaping of the coupling coefficients required by the TR-STIRAP can be approximated by Gaussian functions with high conversion fidelity, thus simplifying the experimental implementation. Finally, a possible application of the new protocol is discussed in the context of single-photon detection in the MIR.

Abstract:In this letter we explore how full frequency conversion can be performed in shorter optical devices by using a STIRAP-like protocol modified by the time rescaling shortcut to adiabaticity. We first show a detailed, step-by-step process of how the coupled equations for two simultaneous three-wave mixing processes can be written in terms of a STIRAP-like system. From the properties of the STIRAP protocol, we know that the ensuing process will result in robust conversion, but require long propagation distances inside the bulk crystal or waveguide. We then apply the time rescaling shortcut to adiabaticty in the conversion process to create a TR-STIRAP protocol, showing that full and robust conversion is also obtained, but at a fraction of the propagation distance. We also show how the original shaping of the coupling coefficients required by the TR-STIRAP can be approximated by Gaussian functions with high conversion fidelity, thus simplifying the experimental implementation. Finally, a possible application of the new protocol is discussed in the context of single-photon detection in the MIR.

Quantum Physics (quant-ph); Optics (physics.optics)

arXiv:2602.18930 [quant-ph]

(or arXiv:2602.18930v2 [quant-ph] for this version)

https://doi.org/10.48550/arXiv.2602.18930 Focus to learn more arXiv-issued DOI via DataCite

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 263 cuvinte