Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchCercetare AI

analiza aiqbench

This research introduces a safety-oriented preprocessing layer for biomedical NLP that prioritizes auditability and the "do-no-harm" principle over maximal accuracy when correcting OCR artifacts. By abstaining from edits under uncertainty, the system effectively recovers performance on noisy datasets while maintaining robustness on clean data, offering a deterministic solution to lexical corruption in large-scale corpora.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

The Signal in the Noise: An Auditable Reliability Layer for Biomedical Text Classification

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2608.28595v1 Announce Type: new Abstract: Biomedical NLP pipelines routinely presuppose clean input text, yet large-scale corpora assembled through automated PDF parsing harbour pervasive OCR-like artifacts, token splits and merges, hyphenation remnants, and character-level corruption, that systematically erode lexical evidence and degrade downstream classifiers. We introduce a conservative, fully auditable spell-correction reliability layer conceived as a safety-oriented preprocessing module rather than a maximal-accuracy corrector: under conditions of uncertainty, the system abstains from editing, in accordance with a medical do-no-harm philosophy. The deterministic architecture couples bounded edit-distance candidate generation with corpus-derived n-gram scoring and a suite of biomedical safety gates that protect domain-critical terminology. We evaluate the layer both intrinsically, on a manually curated benchmark of 2,104 token-level cases, and extrinsically, on a tri-class CORD-19 topic classifier (Prevention, Treatment, Epidemiology) spanning 10,000 examples under a principled four-run protocol (Clean, Noisy, Restored, Safety). Intrinsically, the layer attains 94.61% error-fix recall on synthetic errors with zero harmful edits on negative controls. Downstream, it recovers approximately 80.45% of the noise-induced macro-F1 degradation, elevating macro-F1 from 0.7654 (Noisy) to 0.7717 (Restored) while preserving near-clean performance (Safety: 0.7721). A supplementary case study on 103 real-world OCR-extracted abstracts classified with BioBERT confirms that transformer encoders appeared relatively robust to mild noise, motivating a future grey-box architecture that integrates bounded neural signals and UMLS lexicons without compromising auditability. The system is fully deterministic, artifact-driven, and designed with deployment and auditability in mind.

Abstract:Biomedical NLP pipelines routinely presuppose clean input text, yet large-scale corpora assembled through automated PDF parsing harbour pervasive OCR-like artifacts, token splits and merges, hyphenation remnants, and character-level corruption, that systematically erode lexical evidence and degrade downstream classifiers. We introduce a conservative, fully auditable spell-correction reliability layer conceived as a safety-oriented preprocessing module rather than a maximal-accuracy corrector: under conditions of uncertainty, the system abstains from editing, in accordance with a medical do-no-harm philosophy. The deterministic architecture couples bounded edit-distance candidate generation with corpus-derived n-gram scoring and a suite of biomedical safety gates that protect domain-critical terminology. We evaluate the layer both intrinsically, on a manually curated benchmark of 2,104 token-level cases, and extrinsically, on a tri-class CORD-19 topic classifier (Prevention, Treatment, Epidemiology) spanning 10,000 examples under a principled four-run protocol (Clean, Noisy, Restored, Safety). Intrinsically, the layer attains 94.61% error-fix recall on synthetic errors with zero harmful edits on negative controls. Downstream, it recovers approximately 80.45% of the noise-induced macro-F1 degradation, elevating macro-F1 from 0.7654 (Noisy) to 0.7717 (Restored) while preserving near-clean performance (Safety: 0.7721). A supplementary case study on 103 real-world OCR-extracted abstracts classified with BioBERT confirms that transformer encoders appeared relatively robust to mild noise, motivating a future grey-box architecture that integrates bounded neural signals and UMLS lexicons without compromising auditability. The system is fully deterministic, artifact-driven, and designed with deployment and auditability in mind.

6 pages. Accepted at the 2026 14th International Conference on Bioinformatics and Computational Biology (ICBCB 2026), Kitakyushu, Japan; to appear in IEEE Conference Proceedings (IEEE Xplore). Code: this https URL

Artificial Intelligence (cs.AI); Computation and Language (cs.CL); Machine Learning (cs.LG)

arXiv:2608.28595 [cs.AI]

(or arXiv:2608.28595v1 [cs.AI] for this version)

Text integral sub licența deschisă a publicației · 276 cuvinte

Subiecte conexe