Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchSiguranță AI

analiza aiqbench

This research reframes LLM safety monitoring as a graded detectability problem rather than a binary capability issue, quantifying the "oversight gap" where single-trace monitors fail to capture signals that require multi-execution context. The study demonstrates that improving monitor performance depends less on model intelligence and more on defining specific properties to check and implementing correct comparison procedures. Consequently, relying solely on LLM judges for benchmark validation introduces significant directional biases, necessitating mechanically proven construction validity for hyperproperty benchmarks instead of audits by models.
Surse care acoperăarXiv, AI Alignment Forum, LessWrong, Fortune
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

The Oversight Gap: What LLM Safety Monitors Miss, and Why It Is Not Capability

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2609.07162v1 Announce Type: new Abstract: Several properties safety monitors are asked to certify, among them cross-tenant noninterference, sandbagging and evaluation awareness, are 2-safety hyperproperties, witnessed only by two executions. The standard consequence is a binary impossibility: one trace cannot decide them. We replace the binary with a measurement. A tight bound puts the balanced accuracy of any single-trace monitor at $\tfrac12+\tfrac12\,TV(P_0,P_1)$, turning undecidability into a graded detectability frontier and defining an oversight gap: a monitor's shortfall below it. On a leak family with closed-form $TV$, nine LLM monitors are optimal at $TV=0$ but capture little signal as $TV$ grows; at $TV=1$, where a 20-line membership check scores $100\%$, they average $60.9\%$. That shortfall is mostly not capability: naming what to check closes $61\%$ of it while leaving the $TV=0$ control at chance. The same split runs through a $2{\times}2$ factorial: an imagined second run leaves monitors at chance ($50.4\%$) while the same rule on an executed second run reaches $90.0\%$, and a stored oracle without a comparison procedure yields only $68.2\%$. Information and procedure are each necessary and neither is capability. Under nondeterminism, replay tracks a closed-form $k$-replay curve only under the right projection, and a projection frontier shows the resulting dilemma is forced: narrow misses $98.6\%$ of off-channel leaks, broad flags $75.7\%$ of clean traffic, and attainable accuracy decays like $1/(qm)$ in the benign-variation rate and the channel count. Finally, two frontier LLM judges certified an earlier version of our own benchmark as sound while a sign test found a directional bias ($p=2.7\times10^{-5}$) that invalidated three of our findings. Construction validity for hyperproperty benchmarks should be proved mechanically, not audited by models.

Abstract:Several properties safety monitors are asked to certify, among them cross-tenant noninterference, sandbagging and evaluation awareness, are 2-safety hyperproperties, witnessed only by two executions. The standard consequence is a binary impossibility: one trace cannot decide them. We replace the binary with a measurement. A tight bound puts the balanced accuracy of any single-trace monitor at $\tfrac12+\tfrac12\,TV(P_0,P_1)$, turning undecidability into a graded detectability frontier and defining an oversight gap: a monitor's shortfall below it. On a leak family with closed-form $TV$, nine LLM monitors are optimal at $TV=0$ but capture little signal as $TV$ grows; at $TV=1$, where a 20-line membership check scores $100\%$, they average $60.9\%$. That shortfall is mostly not capability: naming what to check closes $61\%$ of it while leaving the $TV=0$ control at chance. The same split runs through a $2{\times}2$ factorial: an imagined second run leaves monitors at chance ($50.4\%$) while the same rule on an executed second run reaches $90.0\%$, and a stored oracle without a comparison procedure yields only $68.2\%$. Information and procedure are each necessary and neither is capability. Under nondeterminism, replay tracks a closed-form $k$-replay curve only under the right projection, and a projection frontier shows the resulting dilemma is forced: narrow misses $98.6\%$ of off-channel leaks, broad flags $75.7\%$ of clean traffic, and attainable accuracy decays like $1/(qm)$ in the benign-variation rate and the channel count. Finally, two frontier LLM judges certified an earlier version of our own benchmark as sound while a sign test found a directional bias ($p=2.7\times10^{-5}$) that invalidated three of our findings. Construction validity for hyperproperty benchmarks should be proved mechanically, not audited by models.

11 pages, 3 figures. Under review

Machine Learning (cs.LG); Cryptography and Security (cs.CR)

arXiv:2609.07162 [cs.LG]

(or arXiv:2609.07162v1 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2609.07162 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 372 cuvinte

Subiecte conexe