Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

În afara temei aiqbench

În afara temei aiqbench

Această știre a fost preluată de la o sursă pe care o urmărim, dar nu ține de domeniul AI sau cuantic, așa că nu există o perspectivă aiqbench pentru ea.

The MS Unidirectional Current as a Generalization of the ABC Absorption Current

arXiv2 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2608.29969v1 Announce Type: new Abstract: For a free scalar particle in one spatial dimension, in a single-pass half-line geometry, we compare the absorbing Robin boundary condition with the generalized Marchewka--Schuss (MS) unidirectional-current family. Robin absorption is characterized by a single parameter $\kappa>0$: once $\kappa$ is specified, its momentum-dependent absorption profile is fixed. In the generalized MS construction, by contrast, the detector response is described by a spectral function $\lambda(k)$, subject to the positivity and subnormalization conditions of the detection law. We show that every Robin choice of $\kappa$ corresponds to the particular MS calibration $\lambda_\kappa(k)=\pi\kappa/(k+\kappa)^2$, which reproduces the complete Robin absorption current for every admissible one-sided spectral amplitude and at every time. Thus the entire one-parameter Robin absorption family is contained within the generalized MS family. The MS construction is more general: the choice $\lambda_{\rm full}(k)=\pi/(4k)$ gives unit absorption efficiency for every wave number, which cannot be achieved by any fixed Robin parameter. In this precise sense, the generalized MS detector process extends the Robin absorbing-boundary family. We also compare their asymptotic behavior in the ballistic fixed-ray regime and in the fixed-distance late-time limit.

Abstract:For a free scalar particle in one spatial dimension, in a single-pass half-line geometry, we compare the absorbing Robin boundary condition with the generalized Marchewka--Schuss (MS) unidirectional-current family. Robin absorption is characterized by a single parameter $\kappa>0$: once $\kappa$ is specified, its momentum-dependent absorption profile is fixed. In the generalized MS construction, by contrast, the detector response is described by a spectral function $\lambda(k)$, subject to the positivity and subnormalization conditions of the detection law. We show that every Robin choice of $\kappa$ corresponds to the particular MS calibration $\lambda_\kappa(k)=\pi\kappa/(k+\kappa)^2$, which reproduces the complete Robin absorption current for every admissible one-sided spectral amplitude and at every time. Thus the entire one-parameter Robin absorption family is contained within the generalized MS family. The MS construction is more general: the choice $\lambda_{\rm full}(k)=\pi/(4k)$ gives unit absorption efficiency for every wave number, which cannot be achieved by any fixed Robin parameter. In this precise sense, the generalized MS detector process extends the Robin absorbing-boundary family. We also compare their asymptotic behavior in the ballistic fixed-ray regime and in the fixed-distance late-time limit.

arXiv:2608.29969 [quant-ph]

(or arXiv:2608.29969v1 [quant-ph] for this version)

https://doi.org/10.48550/arXiv.2608.29969 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 270 cuvinte

Subiecte conexe