Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchMachine learning

analiza aiqbench

This research addresses a critical bottleneck in medical AI by demonstrating that fovea-centered spatial normalization significantly improves the generalization of deep learning models across heterogeneous OCT datasets. By mitigating geometric domain shifts inherent to different acquisition protocols, this preprocessing strategy enhances the robustness required for reliable biomarker extraction in neurodegenerative disease analysis.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Spatial Normalization for Cross-Domain Retinal Layer Segmentation in Optical Coherence Tomography

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2607.16065v1 Announce Type: cross Abstract: Retinal layer segmentation in Optical Coherence Tomography (OCT) is a fundamental step for extracting quantitative biomarkers of retinal structure. Indeed, there is a growing interest in the analysis of OCTs in the context of neurodegenerative diseases. However, segmentation remains challenging due to speckle noise, shadowing artifacts, low contrast between adjacent layers, anatomical variability across subjects, and domain shifts arising from different acquisition protocols and clinical populations. While deep learning methods have achieved remarkable performance, their robustness and generalization across heterogeneous datasets remain limited. In this work, we investigate the role of spatial normalization as a preprocessing strategy to mitigate geometric domain shifts and improve the consistency of retinal layer segmentation. Inspired by standard practices in neuroimaging, we introduce a fovea-centered normalization framework that aligns OCT volumes into a common anatomical reference. We perform a comprehensive evaluation of state-of-the-art deep learning architectures. To provide a comprehensive assessment of segmentation quality, we combine conventional overlap-based metrics at B-scan level with topology-aware metrics at A-scan level and thickness-based measures at the en-face level. In cases where a ground truth is not available, we propose topology violation quantitative metrics that do not require ground truth annotations and a thickness-based qualitative assessment that captures structural consistency and clinically relevant patterns at the en-face level. The results demonstrate the importance of spatial normalization in OCT segmentation pipelines toward the development of robust and clinically meaningful retinal analysis tools, enabling reliable biomarker extraction and downstream computational analysis in neurodegenerative research.

Abstract:Retinal layer segmentation in Optical Coherence Tomography (OCT) is a fundamental step for extracting quantitative biomarkers of retinal structure. Indeed, there is a growing interest in the analysis of OCTs in the context of neurodegenerative diseases. However, segmentation remains challenging due to speckle noise, shadowing artifacts, low contrast between adjacent layers, anatomical variability across subjects, and domain shifts arising from different acquisition protocols and clinical populations. While deep learning methods have achieved remarkable performance, their robustness and generalization across heterogeneous datasets remain limited. In this work, we investigate the role of spatial normalization as a preprocessing strategy to mitigate geometric domain shifts and improve the consistency of retinal layer segmentation. Inspired by standard practices in neuroimaging, we introduce a fovea-centered normalization framework that aligns OCT volumes into a common anatomical reference. We perform a comprehensive evaluation of state-of-the-art deep learning architectures. To provide a comprehensive assessment of segmentation quality, we combine conventional overlap-based metrics at B-scan level with topology-aware metrics at A-scan level and thickness-based measures at the en-face level. In cases where a ground truth is not available, we propose topology violation quantitative metrics that do not require ground truth annotations and a thickness-based qualitative assessment that captures structural consistency and clinically relevant patterns at the en-face level. The results demonstrate the importance of spatial normalization in OCT segmentation pipelines toward the development of robust and clinically meaningful retinal analysis tools, enabling reliable biomarker extraction and downstream computational analysis in neurodegenerative research.

Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)

arXiv:2607.16065 [cs.CV]

(or arXiv:2607.16065v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2607.16065 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 343 cuvinte

Subiecte conexe