analiza aiqbench
This paper applies contrastive learning to decode imagined speech from EEG by aligning brain signals with a frozen pretrained text encoder. It reports accuracy comparable to a closed-set classifier on the Chisco dataset, with five subjects and 39 intent categories. Readers should note that the evaluation is small and the results are preliminary, so the claimed gains in retrieval and reliability ranking need validation on larger datasets and with more subjects.
Semantic Alignment of EEG and Text: A Contrastive Learning Framework for Decoding Imagined Speech
arXiv:2610.20766v1 Announce Type: new Abstract: Imagined speech decoding from EEG offers a promising route toward naturalistic brain-computer interfaces. Traditional closed-set classifiers treat semantic categories as independent labels and do not explicitly exploit relationships among linguistic intents, limiting output flexibility. We adapt a multimodal contrastive learning framework to imagined speech, aligning EEG trials with language representations in the embedding space of a frozen pretrained text encoder. An EEG encoder is trained with a composite objective combining semantically reweighted EEG-sentence alignment and text-prototype-based class discrimination, encouraging semantic structure while preserving separability among 39 intent categories. We evaluate the approach on the Chisco imagined speech dataset across five subjects, reporting Top-k accuracy, macro-F1, and balanced pairwise matching accuracy (2v2). We also investigate maximum EEG-text cosine similarity (MaxCosine) as an intrinsic indicator of decoding reliability and probe semantic structure beyond category labels using five evaluation-time semantic axes and a qualitative Semantic Gallery Probe (SGP) with previously unseen candidate sentences. The contrastive framework achieved decoding performance comparable to a task-optimized closed-set classifier while mapping EEG into a frozen language embedding space. MaxCosine identified subsets of held-out trials with higher Top-1 and Top-5 accuracy across subjects. Evaluation-time semantic axes showed mean agreement above the 50% chance reference across all five dimensions, and the SGP qualitatively illustrated direct comparison with unseen candidate sentences. Together, these findings suggest that EEG-language alignment can retain comparable fixed-intent decoding while supporting similarity-based retrieval, intrinsic reliability ranking, and evaluation of broader semantic structure.
Abstract:Imagined speech decoding from EEG offers a promising route toward naturalistic brain-computer interfaces. Traditional closed-set classifiers treat semantic categories as independent labels and do not explicitly exploit relationships among linguistic intents, limiting output flexibility. We adapt a multimodal contrastive learning framework to imagined speech, aligning EEG trials with language representations in the embedding space of a frozen pretrained text encoder. An EEG encoder is trained with a composite objective combining semantically reweighted EEG-sentence alignment and text-prototype-based class discrimination, encouraging semantic structure while preserving separability among 39 intent categories. We evaluate the approach on the Chisco imagined speech dataset across five subjects, reporting Top-k accuracy, macro-F1, and balanced pairwise matching accuracy (2v2). We also investigate maximum EEG-text cosine similarity (MaxCosine) as an intrinsic indicator of decoding reliability and probe semantic structure beyond category labels using five evaluation-time semantic axes and a qualitative Semantic Gallery Probe (SGP) with previously unseen candidate sentences. The contrastive framework achieved decoding performance comparable to a task-optimized closed-set classifier while mapping EEG into a frozen language embedding space. MaxCosine identified subsets of held-out trials with higher Top-1 and Top-5 accuracy across subjects. Evaluation-time semantic axes showed mean agreement above the 50% chance reference across all five dimensions, and the SGP qualitatively illustrated direct comparison with unseen candidate sentences. Together, these findings suggest that EEG-language alignment can retain comparable fixed-intent decoding while supporting similarity-based retrieval, intrinsic reliability ranking, and evaluation of broader semantic structure.
Machine Learning (cs.LG); Neurons and Cognition (q-bio.NC)
arXiv:2610.20766 [cs.LG]
(or arXiv:2610.20766v1 [cs.LG] for this version)
https://doi.org/10.48550/arXiv.2610.20766 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 334 cuvinte
Subiecte conexe
Joint Text-Audio Alignment for EEG-to-Text Decoding in Chinese Speech Production and Perception
arXiv · 29 iul. 2026
Brain-CLIPLM: Semantic Compression for EEG-to-Text Decoding
arXiv · 6 iun. 2026
Margin-Regularized Structured Semantic Alignment for Brain-Language Correspondence
arXiv · 20 aug. 2026
Brain-CLIPLM: Semantic Compression for EEG-to-Text Decoding
arXiv · 20 iul. 2026